Worked example
Example: Air-saturated water 25 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas | Oxygen O₂ |
| Water temperature | 25.000 °C |
| Total pressure above the water (absolute) | 1.0132 bar |
| Gas share of the dry gas phase (air: O₂ 20.95 %, N₂ 78.08 %) | 20.950 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Henry's constant | 4,364.1 MPa |
| Gas partial pressure | 20.564 kPa |
| Mole fraction dissolved | 4.7119 ppm |
| Concentration | 8.3446 mg/L |
Open this example in the calculator and change any input.
Formula
\(p_g = y\,(p - p_s(T)), \quad x = \frac{p_g}{k_H(T)}, \quad c = x\frac{\rho_w}{M_w}M_g\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{gas}\) | Gas | - |
| \(T\) | Water temperature | K |
| \(p\) | Total pressure above the water (absolute) | Pa |
| \(y\) | Gas share of the dry gas phase (air: O₂ 20.95 %, N₂ 78.08 %) | - |
| \(k_H\) | Henry's constant | Pa |
| \(p_g\) | Gas partial pressure | Pa |
| \(x\) | Mole fraction dissolved | - |
| \(c\) | Concentration | kg/m³ |
Method and standards
IAPWS G7-04.
Where it is used
- Feedwater and make-up oxygen.
- Deaerator and scavenger design.
Common mistakes
- Using total pressure as the gas partial pressure.
Assumptions and limits
- Dilute, ideal gas phase: partial pressure without fugacity or Poynting corrections, so the result grows less accurate at high pressure (a note appears above 10 bar).
- For CO₂ and H₂S the result is the molecular dissolved gas only; bicarbonate, carbonate and HS⁻ formed by ionisation are not included.
- The water vapour pressure is from IAPWS-IF97; the Henry's constants of IAPWS G7-04 use the Wagner–Pruss vapour pressure internally. The difference is negligible here.
References
- IAPWS G7-04
- Guideline on the Henry's Constant and Vapor-Liquid Distribution Constant for Gases in H₂O and D₂O at High Temperatures (2004); dilute solution x = p_g/k_H; water density from IAPWS-IF97
Questions and answers
Why does hot water hold less oxygen?
Henry's constant rises with temperature up to about 100 °C, and the water vapour pressure crowds out the gas.
Air-saturated water at 25 °C?
Around 8 mg/L of oxygen.
Use?
Feedwater oxygen before deaeration and the scavenger dose it needs.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.