FireCADCalc

Dissolved Oxygen (or Other Gas) Saturation in Water

Equilibrium concentration of oxygen, nitrogen, CO₂ or other gases dissolved in water at a temperature and partial pressure (IAPWS G7-04 Henry's constant).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Water treatment plantDeaerator and feedwater system

Inputs

Examples: Air-saturated water 25 °CHot well 50 °C, N2CO2 at 80 °C, 1.5 bar total

Results

IAPWS G7-04 is built for high temperatures; near ambient it may differ by a few per cent from precise low-temperature data.

Henry's constant4,364.1MPa
Gas partial pressure20.564kPa
Mole fraction dissolved4.7119ppm
Concentration8.3446mg/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air-saturated water 25 °C. The inputs, in the units selected above:

InputValue
GasOxygen O₂
Water temperature25.000 °C
Total pressure above the water (absolute)1.0132 bar
Gas share of the dry gas phase (air: O₂ 20.95 %, N₂ 78.08 %)20.950 %

Applying the formula below gives:

ResultValue
Henry's constant4,364.1 MPa
Gas partial pressure20.564 kPa
Mole fraction dissolved4.7119 ppm
Concentration8.3446 mg/L

Open this example in the calculator and change any input.

Formula

\(p_g = y\,(p - p_s(T)), \quad x = \frac{p_g}{k_H(T)}, \quad c = x\frac{\rho_w}{M_w}M_g\)

Variables

Symbol Meaning SI unit
\(\text{gas}\) Gas -
\(T\) Water temperature K
\(p\) Total pressure above the water (absolute) Pa
\(y\) Gas share of the dry gas phase (air: O₂ 20.95 %, N₂ 78.08 %) -
\(k_H\) Henry's constant Pa
\(p_g\) Gas partial pressure Pa
\(x\) Mole fraction dissolved -
\(c\) Concentration kg/m³

Method and standards

IAPWS G7-04.

Where it is used

  • Feedwater and make-up oxygen.
  • Deaerator and scavenger design.

Common mistakes

  • Using total pressure as the gas partial pressure.

Assumptions and limits

  • Dilute, ideal gas phase: partial pressure without fugacity or Poynting corrections, so the result grows less accurate at high pressure (a note appears above 10 bar).
  • For CO₂ and H₂S the result is the molecular dissolved gas only; bicarbonate, carbonate and HS⁻ formed by ionisation are not included.
  • The water vapour pressure is from IAPWS-IF97; the Henry's constants of IAPWS G7-04 use the Wagner–Pruss vapour pressure internally. The difference is negligible here.

References

  • IAPWS G7-04
  • Guideline on the Henry's Constant and Vapor-Liquid Distribution Constant for Gases in H₂O and D₂O at High Temperatures (2004); dilute solution x = p_g/k_H; water density from IAPWS-IF97

Questions and answers

Why does hot water hold less oxygen?

Henry's constant rises with temperature up to about 100 °C, and the water vapour pressure crowds out the gas.

Air-saturated water at 25 °C?

Around 8 mg/L of oxygen.

Use?

Feedwater oxygen before deaeration and the scavenger dose it needs.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators