Worked example
Example: CO2 at 180 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas | Carbon dioxide CO₂ |
| Saturation temperature | 180.00 °C |
| Gas in the water (by mass) | 50.000 ppb |
Applying the formula below gives:
| Result | Value |
|---|---|
| Distribution constant y/x | 584.02 |
| Gas in the steam (by mass) | 29,201 ppb |
| Saturation pressure | 10.026 bar |
Open this example in the calculator and change any input.
Formula
\(K_D = \frac{y}{x}, \quad w_s = K_D w_w\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{gas}\) | Gas | - |
| \(T\) | Saturation temperature | K |
| \(w_w\) | Gas in the water (by mass) | - |
| \(K_D\) | Distribution constant y/x | - |
| \(w_s\) | Gas in the steam (by mass) | - |
| \(p_{sat}\) | Saturation pressure | Pa |
Method and standards
IAPWS G7-04.
Where it is used
- Condensate corrosion studies.
- Deaerator and degasser design.
Common mistakes
- Using K_D at the wrong temperature.
Assumptions and limits
- Equilibrium, dilute.
- For CO₂ and H₂S the water figure is the molecular gas only, not total CO₂ or sulphide: bicarbonate, carbonate and HS⁻ do not distribute to steam by K_D.
- A result above 100 % gas in the steam is rejected; above 1 % the dilute-solution assumption no longer holds and a warning is given.
References
- IAPWS G7-04
- Guideline on the Henry's Constant and Vapor-Liquid Distribution Constant for Gases in H₂O and D₂O at High Temperatures (2004)
Questions and answers
Why does CO₂ end up in condensate?
Bicarbonate breaks down in the boiler; the CO₂ goes with the steam and redissolves as carbonic acid where steam condenses.
K_D near the critical point?
It falls toward 1: gases share almost equally between steam and water.
Ammonia and amines?
Not covered by this guideline; their distribution ratios come from other data.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.