FireCADCalc

Condensate Contamination Share from a Tracer (Conductivity, Sodium)

Share of contaminant (juice, cooling water, process liquor) in returned condensate from a tracer such as conductivity or sodium, and the contaminant flow.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: Juice leak by conductivityCooling water leak by sodium

Any tracer in consistent units: µS/cm, ppb Na, ppm TOC.

Results

If the tracer is conductivity: it also responds to CO₂ and amines, so cation conductivity, sodium or TOC is sharper.

Contaminant share of the condensate2,501.3ppm
Contaminant flow125.06kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Juice leak by conductivity. The inputs, in the units selected above:

InputValue
Tracer in clean condensate2.0000 -
Tracer in the contaminant4,000.0 -
Tracer in the mixed condensate12.000 -
Condensate returned50.000 t/h

Applying the formula below gives:

ResultValue
Contaminant share of the condensate2,501.3 ppm
Contaminant flow125.06 kg/h

Open this example in the calculator and change any input.

Formula

\(f = \frac{\kappa_m - \kappa_c}{\kappa_x - \kappa_c}, \quad \dot m_x = f\,\dot m\)

Variables

Symbol Meaning SI unit
\(\kappa_c\) Tracer in clean condensate -
\(\kappa_x\) Tracer in the contaminant -
\(\kappa_m\) Tracer in the mixed condensate -
\(\dot m\) Condensate returned kg/s
\(f\) Contaminant share of the condensate -
\(\dot m_x\) Contaminant flow kg/s

Method and standards

Tracer balance.

Where it is used

  • Sugar mill condensate monitoring.
  • Condenser leak detection.

Common mistakes

  • Conductivity of a different temperature basis.

Assumptions and limits

  • Linear mixing of the tracer. Sodium and TOC mix linearly by mass; conductivity is only approximately additive and depends on temperature, so use temperature-compensated readings and treat the share as an estimate.
  • The mixed reading must lie between the clean and contaminant readings; otherwise the inputs are rejected.

References

  • Two-component tracer mass balance

Questions and answers

Why does sugar in condensate matter?

Sugar breaks down in the boiler to organic acids, dropping pH and foaming.

Which tracer?

Sodium for cooling-water leaks, TOC or a sugar test for juice, conductivity as a first alarm.

What then?

Dump the condensate until the leak is found; use the boiler upset calculator to plan recovery.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.