Worked example
Example: Drum water 70 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Sample line bore | 6.0000 mm |
| Line length | 40.000 m |
| Sample flow (cold) | 0.50000 L/min |
| Sample pressure (absolute) | 70.000 bar |
| Sample | Water (liquid; saturated water at the saturation temperature) |
| Sample temperature (steam or water) | 285.00 °C |
| Cooled sample temperature | 25.000 °C |
| Cooling water rise | 8.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Transit time in the line | 2.2619 min |
| Sample velocity in the line (cold) | 0.29473 m/s |
| Cooler duty | 9.6218 kW |
| Cooling water | 1,034.2 kg/h |
Open this example in the calculator and change any input.
Formula
\(t_l = \frac{\pi d^2 L}{4\dot V}, \quad v = \frac{4\dot V}{\pi d^2}, \quad \dot m = \dot V\rho(T_2), \quad \dot Q = \dot m[h(p, T_1) - h(T_2)], \quad \dot m_w = \frac{\dot Q}{c_w\Delta T_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d\) | Sample line bore | m |
| \(L\) | Line length | m |
| \(\dot V\) | Sample flow (cold) | m³/s |
| \(p\) | Sample pressure (absolute) | Pa |
| \(\text{sample}\) | Water (liquid) or steam (dry saturated or superheated) | – |
| \(T_1\) | Sample temperature (steam or water) | K |
| \(T_2\) | Cooled sample temperature | K |
| \(\Delta T_w\) | Cooling water rise | K |
| \(t_l\) | Transit time in the line | s |
| \(v\) | Sample velocity in the line (cold) | m/s |
| \(\dot Q\) | Cooler duty | W |
| \(\dot m_w\) | Cooling water | kg/s |
| \(\dot m\) | Sample mass flow | kg/s |
| \(\rho(T_2)\) | Density of the cooled sample | kg/m³ |
| \(c_w\) | Cooling water specific heat, 4 186.8 | J/(kg·K) |
Method and standards
Continuity; energy balance.
Where it is used
- Sampling system design.
Common mistakes
- Hot volume flow used for lag.
Assumptions and limits
- Steady flow.
- The cooled sample is at 1 atm; cooling water c_w = 4 186.8 J/(kg·K).
- The 1.5–2 m/s velocity is common practice, not a cited limit; lower velocities are flagged.
- At the saturation temperature the sample choice decides the state: saturated water, or dry saturated steam (the duties differ by the latent heat). A water sample above, or a steam sample below, the saturation temperature is rejected. Above the critical pressure the state follows from pressure and temperature alone.
References
- Continuity for the lag; energy balance with IAPWS-IF97 enthalpies for the cooler
Questions and answers
Why does lag matter?
A long, slow line shows a chemistry upset many minutes after it happened.
Why velocity?
Iron and copper particles settle in slow lines and give low readings.
Steam samples?
Condense and cool to 25 °C so analysers read correctly.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.