Blowdown Flash and Quench Water to a Discharge Temperature

Flash steam and residual water from boiler blowdown in a flash vessel (IF97), and the cold water to mix in so the drain leaves below a discharge temperature.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)BoilerFlash vessel and condensate

Inputs

Examples: 1.5 t/h from 46 barSmall boiler

Results

Recovering the flash steam and passing the residual water through a heat exchanger first cuts both heat loss and quench water.

Flash steam471.83kg/h
Residual water from the vessel1,028.2kg/h
Quench (cooling) water1,375.7kg/h
Total drain2,403.8kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.5 t/h from 46 bar. The inputs, in the units selected above:

InputValue
Blowdown flow1,500.0 kg/h
Drum pressure (absolute)46.000 bar
Flash vessel pressure (absolute)1.0132 bar
Allowed discharge temperature60.000 °C
Cooling water temperature30.000 °C

Applying the formula below gives:

ResultValue
Flash steam471.83 kg/h
Residual water from the vessel1,028.2 kg/h
Quench (cooling) water1,375.7 kg/h
Total drain2,403.8 kg/h

Open this example in the calculator and change any input.

Formula

\(x = \frac{h_f(p_d) - h_f(p_v)}{h_{fg}(p_v)}, \quad \dot m_c = \dot m_b(1 - x)\frac{h_f(p_v) - h(T_d)}{h(T_d) - h(T_c)}\)

Variables

Symbol Meaning SI unit
\(\dot m_b\) Blowdown flow kg/s
\(p_d\) Drum pressure (absolute) Pa
\(p_v\) Flash vessel pressure (absolute) Pa
\(T_d\) Allowed discharge temperature K
\(T_c\) Cooling water temperature K
\(\dot m_f\) Flash steam kg/s
\(\dot m_l\) Residual water from the vessel kg/s
\(\dot m_c\) Quench (cooling) water kg/s
\(\dot m_t\) Total drain kg/s

Method and standards

Energy balance.

Where it is used

  • Blowdown system design.
  • Effluent compliance.

Common mistakes

  • Ignoring the flash.

Assumptions and limits

  • Adiabatic vessel; the flash steam leaves the vessel (vented or recovered). If it is condensed into the drain, the quench water needed is higher.
  • The residual water is mixed with the cooling water at atmospheric pressure; with a pressurised flash vessel, any second flash when the water is let down to the drain is not modelled.

References

  • Flash and mixing energy balances with IAPWS-IF97 enthalpies; the discharge limit is the user's consent value

Questions and answers

Why quench blowdown?

Drains and sewers have temperature limits; hot water also damages pipes and creates vapour.

How much flashes?

From a 46 bar(a) drum to atmosphere, about 30 % of the blowdown flashes.

Better option?

Recover flash steam to the deaerator and preheat make-up with the residual water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.