Effluent Design Mean for a Permit Limit at a Reliability Level

Mean (median) effluent value a process must achieve so a permit limit is met at a chosen reliability, from a log-normal spread with geometric standard deviation.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 15 mg/L monthly limit at 99 %, sg 1.2520 mg/L weekly limit at 99.9 %, sg 1.25Copper 10 ug/L at 99.9 %, sg 1.66

Accepted: 1E-6 to 10,000 mg/L
Accepted: 50 to 99.999 %
Accepted: 1.01 to 5

Results

The effluent is assumed log-normal with the stated geometric standard deviation, kept the same at the lower design level. A typical rule: to meet a limit 95 % of the time, design for about half the limit.

Standard normal deviate2.3263
Required geometric mean (median)8.9258mg/L
Required arithmetic mean9.1508mg/L
Coefficient of reliability (mean/limit)0.61005

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 mg/L monthly limit at 99 %, sg 1.25. The inputs, in the units selected above:

InputValue
Permit limit15.000 mg/L
Required reliability99.000 %
Geometric standard deviation (P84.1/P50)1.2500 -

Applying the formula below gives:

ResultValue
Standard normal deviate2.3263
Required geometric mean (median)8.9258 mg/L
Required arithmetic mean9.1508 mg/L
Coefficient of reliability (mean/limit)0.61005

Open this example in the calculator and change any input.

Formula

\(M_g = \frac{C_{lim}}{s_g^{\,z}}, \quad \bar C = M_g\,e^{(\ln s_g)^2/2}, \quad z = \Phi^{-1}(R)\)

Variables

Symbol Meaning SI unit
\(C_{lim}\) Permit limit kg/m³
\(R\) Required reliability -
\(s_g\) Geometric standard deviation (P84.1/P50) -
\(z\) Standard normal deviate -
\(M_g\) Required geometric mean (median) kg/m³
\(\bar C\) Required arithmetic mean kg/m³
\(COR\) Coefficient of reliability (mean/limit) -

Method and standards

Log-normal statistics of effluent quality.

Where it is used

  • Setting process design targets from permits.
  • Judging whether a process can meet a new limit.

Common mistakes

  • Using the arithmetic standard deviation as s_g.
  • Mixing monthly and weekly reliability levels.

Assumptions and limits

  • Log-normal effluent; stationary variability.

Questions and answers

How do I get s_g?

Plot the effluent data on log-probability paper and divide the value at 84.1 % by the value at 50 %; Designers give 1.25 for well-run secondary effluent TSS.

Why is the design mean so much lower than the limit?

With day-to-day variability, a process averaging the limit would exceed it half the time; reliability requires a lower centre.

What do the defaults represent?

A 15 mg/L monthly limit at 99 % reliability with s_g = 1.25: median 8.9 mg/L (z = 2.33) and arithmetic mean 9.2 mg/L, a coefficient of reliability of 0.61.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 4-3, Examples 4-2 and 4-3 and Fig. 4-6 (Niku et al. 1979)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.