Worked example
Example: Baffled tank, broad curve. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean residence time of the tracer curve | 1.6000 h |
| Variance of the tracer curve (min²) | 600.00 - |
| Flow through the basin | 2,400.0 m³/d |
| Basin volume | 200.00 m³ |
| Flow path length | 60.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Theoretical detention time | 2.0000 h |
| Normalised mean time | 0.80000 |
| Normalised variance | 0.041667 |
| Dispersion number (open vessel, σθ² = 2d) | 0.020833 |
| Dispersion number (closed vessel) | 0.021286 |
| Equivalent tanks in series | 24.000 |
| Coefficient of dispersion (closed d) | 0.010643 m²/s |
Open this example in the calculator and change any input.
Formula
\(\sigma_\theta^2 = \frac{\sigma^2}{\tau^2}, \quad d_{open} = \frac{\sigma_\theta^2}{2}, \quad \sigma_\theta^2 = 2d - 2d^2\left(1 - e^{-1/d}\right), \quad N = \frac{1}{\sigma_\theta^2}, \quad D = d\frac{L^2}{\tau}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\bar t\) | Mean residence time of the tracer curve | s |
| \(\sigma^2\) | Variance of the tracer curve (min²) | - |
| \(Q\) | Flow through the basin | m³/s |
| \(V\) | Basin volume | m³ |
| \(L\) | Flow path length | m |
| \(\tau\) | Theoretical detention time | s |
| \(\bar\theta\) | Normalised mean time | - |
| \(\sigma_\theta^2\) | Normalised variance | - |
| \(d_{open}\) | Dispersion number (open vessel, σθ² = 2d) | - |
| \(d_{closed}\) | Dispersion number (closed vessel) | - |
| \(N\) | Equivalent tanks in series | - |
| \(D\) | Coefficient of dispersion (closed d) | m²/s |
Method and standards
Dispersion model of non-ideal flow.
Where it is used
- Contact basin and reactor hydraulic assessment.
- Checking baffle effectiveness.
Common mistakes
- Entering the variance in h² while τ is in minutes.
- Using one channel length for a serpentine basin.
Assumptions and limits
- Pulse tracer; first and second moments from a complete curve.
Questions and answers
Which dispersion number should I use?
For small values (d < 0.01) the open and closed answers agree; for larger values the closed-vessel relation, which accounts for the inlet and outlet boundaries, is more appropriate for basins.
What do the defaults represent?
An illustrative case: Baffled tank, broad curve. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), Appendix I, eqs. I-7 to I-9 and Example I-1; Levenspiel's closed-vessel relation