Worked example
Example: 100 ha reservoir, 27/30 °C, 50 %, 3 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water surface temperature | 27.000 °C |
| Air temperature | 30.000 °C |
| Relative humidity | 50.000 % |
| Wind speed at 9 m | 3.0000 m/s |
| Meyer coefficient (0.36 large deep, 0.50 small shallow) | 0.36000 - |
| Water surface area | 100.00 ha |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation vapour pressure at water temperature | 26.761 mmHg |
| Air vapour pressure | 15.926 mmHg |
| Evaporation (mm/day) | 6.5335 |
| Volume lost per day | 6,533.5 m³ |
Open this example in the calculator and change any input.
Formula
\(E = C(e_w - e_a)\left(1 + \frac{u_9}{16}\right)\ \ (\mathrm{mm/day};\ e\ \mathrm{in\ mm\ Hg};\ u_9\ \mathrm{in\ km/h})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t_w\) | Water surface temperature | K |
| \(t_a\) | Air temperature | K |
| \(\varphi\) | Relative humidity | - |
| \(u_9\) | Wind speed at 9 m | m/s |
| \(C\) | Meyer coefficient (0.36 large deep, 0.50 small shallow) | - |
| \(A\) | Water surface area | m² |
| \(e_w\) | Saturation vapour pressure at water temperature | Pa |
| \(e_a\) | Air vapour pressure | Pa |
| \(E\) | Evaporation (mm/day) | - |
| \(V_d\) | Volume lost per day | m³ |
Method and standards
Meyer's formula.
Where it is used
- Raw-water reservoir and ash pond balances.
- Cooling pond water budgets.
Common mistakes
- Using air temperature for e_w.
- Wind at the wrong height.
Assumptions and limits
- Daily averages.
References
- Meyer's formula (Subramanya, Engineering Hydrology, ch. 3); IAPWS-IF97 saturation pressure
Questions and answers
How large is reservoir evaporation in India?
Typically 3–8 mm per day in summer, a significant share of small raw-water ponds.
How can evaporation be reduced?
Deeper, smaller-area storage, windbreaks, floating covers or monolayers.
What do the defaults represent?
A 100 ha raw-water reservoir on a warm, moderately dry day.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.