Best hydraulic section: least wetted perimeter for the area (b = 2y for rectangles; for trapezoids b = 2y(√(1 + z²) − z) and R = y/2). The best of all trapezoids has z = 1/√3 (half hexagon). Check velocity against scour and silting limits; excavation cost may favour wider, shallower channels.

Flow depth1.4437m
Bed width2.8873m
Flow area4.1683m²
Mean velocity1.1995m/s
Hydraulic radius0.72183m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Lined rectangular, 5 m³/s at 1 in 2,000. The inputs, in the units selected above:

InputValue
Discharge18,000 m³/h
Manning's n0.015000 -
Bed slope5.0000e-04 -
Side slope H:V (0 = rectangular)0 -

Applying the formula below gives:

ResultValue
Flow depth1.4437 m
Bed width2.8873 m
Flow area4.1683 m²
Mean velocity1.1995 m/s
Hydraulic radius0.72183 m

Open this example in the calculator and change any input.

Formula

\(R = \frac y2, \quad b = 2y\left(\sqrt{1 + z^2} - z\right), \quad Q = \frac1nAR^{2/3}S^{1/2}\)

Variables

Symbol Meaning SI unit
\(Q\) Discharge m³/s
\(n\) Manning's n -
\(S\) Bed slope -
\(z\) Side slope H:V (0 = rectangular) -
\(y\) Flow depth m
\(b\) Bed width m
\(A\) Flow area m²
\(v\) Mean velocity m/s
\(R\) Hydraulic radius m

Method and standards

Best hydraulic section.

Where it is used

  • Cooling water and effluent channels.
  • Drainage and irrigation channels.

Common mistakes

  • Ignoring freeboard.
  • Exceeding scour velocity for unlined channels.

Assumptions and limits

  • Uniform flow.

References

  • Best hydraulic section with Manning's equation (Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 7)

Questions and answers

Why is it called most economical?

For a given area it has the least wetted perimeter, so least lining and friction.

Is it always the cheapest to build?

Not always: deep narrow channels cost more to excavate; it is a starting point.

What do the defaults represent?

A lined rectangular channel carrying 5 m³/s at 1 in 2,000.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.