Worked example
Example: Lined rectangular, 5 m³/s at 1 in 2,000. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Discharge | 18,000 m³/h |
| Manning's n | 0.015000 - |
| Bed slope | 5.0000e-04 - |
| Side slope H:V (0 = rectangular) | 0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow depth | 1.4437 m |
| Bed width | 2.8873 m |
| Flow area | 4.1683 m² |
| Mean velocity | 1.1995 m/s |
| Hydraulic radius | 0.72183 m |
Open this example in the calculator and change any input.
Formula
\(R = \frac y2, \quad b = 2y\left(\sqrt{1 + z^2} - z\right), \quad Q = \frac1nAR^{2/3}S^{1/2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Discharge | m³/s |
| \(n\) | Manning's n | - |
| \(S\) | Bed slope | - |
| \(z\) | Side slope H:V (0 = rectangular) | - |
| \(y\) | Flow depth | m |
| \(b\) | Bed width | m |
| \(A\) | Flow area | m² |
| \(v\) | Mean velocity | m/s |
| \(R\) | Hydraulic radius | m |
Method and standards
Best hydraulic section.
Where it is used
- Cooling water and effluent channels.
- Drainage and irrigation channels.
Common mistakes
- Ignoring freeboard.
- Exceeding scour velocity for unlined channels.
Assumptions and limits
- Uniform flow.
References
- Best hydraulic section with Manning's equation (Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 7)
Questions and answers
Why is it called most economical?
For a given area it has the least wetted perimeter, so least lining and friction.
Is it always the cheapest to build?
Not always: deep narrow channels cost more to excavate; it is a starting point.
What do the defaults represent?
A lined rectangular channel carrying 5 m³/s at 1 in 2,000.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.