Worked example
Example: 30 m³/s in medium sand. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Discharge | 108,000 m³/h |
| Mean silt diameter | 0.32000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Silt factor | 0.99561 |
| Regime velocity | 0.77243 m/s |
| Area | 38.838 m² |
| Wetted perimeter | 26.017 m |
| Hydraulic mean depth | 1.4982 m |
| Bed slope | 1.6861e-04 |
Open this example in the calculator and change any input.
Formula
\(f = 1.76\sqrt{d_{mm}}, \quad V = \left(\frac{Qf^2}{140}\right)^{1/6}, \quad P = 4.75\sqrt Q, \quad R = \frac{5V^2}{2f}, \quad S = \frac{f^{5/3}}{3340Q^{1/6}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Discharge | m³/s |
| \(d_{mm}\) | Mean silt diameter (used in mm in the formula) | m |
| \(f\) | Silt factor | - |
| \(V\) | Regime velocity | m/s |
| \(A\) | Area | m² |
| \(P\) | Wetted perimeter | m |
| \(R\) | Hydraulic mean depth | m |
| \(S\) | Bed slope | - |
Method and standards
Lacey's equations.
Where it is used
- Irrigation and raw-water canals.
- Exam problems.
Common mistakes
- Using it for lined canals.
- Mixing FPS and SI forms.
Assumptions and limits
- Alluvial channels in regime.
- The silt diameter may be entered in any length unit; the silt factor uses it in mm.
- Lacey's equations are only approximately consistent: A = Q/V and P × R differ slightly; a note shows both.
References
- Lacey's regime equations (Garg, Irrigation Engineering and Hydraulic Structures (Khanna))
Questions and answers
What is regime?
A canal in alluvium that neither silts nor scours on average: its shape and slope adjust to the discharge and silt.
Why does silt size matter?
Coarser silt needs a steeper slope and higher velocity to keep it moving.
What do the defaults represent?
A 30 m³/s canal in medium sand (0.32 mm).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.