FireCADCalc

Water Storage Tank Capacity for a Building or Plant

Daily water demand and storage tank volume from the number of people and demand per head, with days of storage and fire reserve, and tank plan size.

Tank and drum

Inputs

Examples: 200 residents at 135 L/day, one day50 staff at 70 L/day, two days1 000 office users at 45 L/day, 100 m³ fire reserve

Take the figure for your building type from your local code or the client.

Results

Add free board above the water depth and the dead storage below the outlet to get the tank's overall size.

Daily demand27.000m³
Storage needed27.000m³
Plan area of the tank at that depth10.800m²
Diameter of a round tank3.7082m
Side of a square tank3.2863m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 200 residents at 135 L/day, one day. The inputs, in the units selected above:

InputValue
Number of people (or equivalent users)200.00 -
Demand per person per day135.00 L
Days of storage1.0000 -
Fire-fighting reserve0 m³
Water depth in the tank2.5000 m

Applying the formula below gives:

ResultValue
Daily demand27.000 m³
Storage needed27.000 m³
Plan area of the tank at that depth10.800 m²
Diameter of a round tank3.7082 m
Side of a square tank3.2863 m

Open this example in the calculator and change any input.

Formula

\(V_d = N q, \quad V = V_d\, d + V_f\)

\(A = V / h, \quad D = \sqrt{4A/\pi}, \quad s = \sqrt{A}\)

Variables

Symbol Meaning SI unit
\(N\) Number of people (or equivalent users) -
\(q\) Demand per person per day m³
\(d\) Days of storage -
\(V_f\) Fire-fighting reserve m³
\(h\) Water depth in the tank m
\(V_d\) Daily demand m³
\(V\) Storage needed m³
\(A\) Plan area of the tank at that depth m²
\(D\) Diameter of a round tank m
\(s\) Side of a square tank m

Method and standards

Daily demand is people times demand per head; storage is the days required plus any fire reserve. The plan area follows from the water depth.

Where it is used

  • Sizing sumps and overhead tanks.
  • Plant township and canteen water supply.
  • Checking existing storage after a headcount rise.

Common mistakes

  • Leaving out free board and dead storage.
  • Using residential demand for offices.
  • Forgetting the fire reserve must be protected.

Assumptions and limits

  • Average demand; peak pumping sized separately.

References

  • Per-capita demand method (demand per head from the local code or client)

Questions and answers

How big a tank for 200 residents at 135 L/day?

27 m³ for one day; at 2.5 m water depth that is 10.8 m², a 3.7 m round tank or 3.3 m square.

Where does the demand per head come from?

Your local building code or the client's brief; it varies widely with building type.

How is the fire reserve handled?

Added on top, and kept below the domestic outlet so it is never drawn for daily use.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.