Worked example
Example: 10 m channel, 20 m³/s, weir raises to 3 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Discharge | 72,000 m³/h |
| Channel width | 10.000 m |
| Manning's n | 0.025000 - |
| Bed slope | 4.0000e-04 - |
| Depth at the control (start) | 3.0000 m |
| Depth at the end | 2.3000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Normal depth | 1.9803 m |
| Critical depth | 0.74162 m |
| Distance between y₁ and y₂ (upstream +) | 3,172.3 m |
Open this example in the calculator and change any input.
Formula
\(\frac{dx}{dy} = \frac{1 - Fr^2}{S_0 - S_f}, \quad S_f = \left(\frac{nQ}{AR^{2/3}}\right)^2, \quad Fr^2 = \frac{Q^2}{gb^2y^3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Discharge | m³/s |
| \(b\) | Channel width | m |
| \(n\) | Manning's n | - |
| \(S_0\) | Bed slope | - |
| \(y_1\) | Depth at the control (start) | m |
| \(y_2\) | Depth at the end | m |
| \(y_n\) | Normal depth | m |
| \(y_c\) | Critical depth | m |
| \(\Delta x\) | Distance between y₁ and y₂ (upstream +) | m |
Method and standards
GVF equation.
Where it is used
- Intake weirs and cooling water channels.
- Flood levels upstream of structures.
Common mistakes
- Starting from the wrong control.
- Crossing normal depth.
Assumptions and limits
- Rectangular prismatic channel; steady flow.
- A depth very close to normal depth makes the integral converge slowly; a result whose Simpson estimate changes by more than 1 % when the step is halved is flagged.
References
- Gradually varied flow equation dy/dx = (S₀ − S_f)/(1 − Fr²) (Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 9–10)
Questions and answers
How far upstream does a weir raise the water?
The backwater curve approaches normal depth asymptotically; it is common to stop at 1–2 % above normal depth.
Why can't the depths cross normal or critical depth?
The GVF equation is singular there; each zone has its own profile type.
What do the defaults represent?
A 10 m wide channel carrying 20 m³/s on a mild slope with a weir raising the depth to 3 m.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.