FireCADCalc

Runoff Depth by the SCS Curve Number Method

Direct runoff depth from storm rainfall by the SCS curve number method, with retention, initial abstraction, runoff volume and coefficient.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 100 mm storm, CN 80, 100 haSmall 20 mm storm on paved CN 98

Results

S = 25,400/CN − 254 mm. CN from land use, soil hydrologic group and antecedent moisture (USDA TR-55 tables). Use for storm totals, not rainfall intensities.

Potential maximum retention63.500mm
Initial abstraction12.700mm
Runoff depth50.539mm
Runoff volume50,539m³
Runoff coefficient50.539%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 mm storm, CN 80, 100 ha. The inputs, in the units selected above:

InputValue
Storm rainfall100.00 mm
Curve number80.000 -
Initial abstraction ratio0.20000 -
Catchment area100.00 ha

Applying the formula below gives:

ResultValue
Potential maximum retention63.500 mm
Initial abstraction12.700 mm
Runoff depth50.539 mm
Runoff volume50,539 m³
Runoff coefficient50.539 %

Open this example in the calculator and change any input.

Formula

\(S = \frac{25400}{CN} - 254, \quad Q = \frac{(P - \lambda S)^2}{P - \lambda S + S}\ \ (P > \lambda S)\)

Variables

Symbol Meaning SI unit
\(P\) Storm rainfall m
\(CN\) Curve number -
\(\lambda\) Initial abstraction ratio -
\(A\) Catchment area m²
\(S\) Potential maximum retention m
\(I_a\) Initial abstraction m
\(Q\) Runoff depth m
\(V\) Runoff volume m³
\(Q/P\) Runoff coefficient -

Method and standards

SCS runoff equation.

Where it is used

  • Storm drainage and pond sizing.
  • Plant site drainage.

Common mistakes

  • Using CN for the wrong soil group.
  • Applying it to short-duration intensities.

Assumptions and limits

  • Storm totals; average antecedent moisture.

References

  • USDA NRCS
  • National Engineering Handbook part 630
  • ch. 10 (runoff equation)

Questions and answers

What does the curve number mean?

Higher CN means less infiltration: about 98 for paved areas, 70–85 for open ground depending on soil, 30–60 for woods on sandy soil.

Why is there no runoff from small storms?

The first rain fills depressions and soaks in (initial abstraction) before any runs off.

What do the defaults represent?

A 100 mm storm on a 100 ha catchment with CN 80.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...