Worked example
Example: Direct steam, 12 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| OD wood | 50,000 kg |
| Wood specific heat | 1.3400 kJ/(kg·K) |
| Liquor and water (incl. chip water) | 200,000 kg |
| Liquor specific heat | 3.9000 kJ/(kg·K) |
| Charge temperature | 70.000 °C |
| Cooking temperature | 170.00 °C |
| Steam pressure (absolute) | 12.000 bar |
| Heating | Direct steam (condensate stays) |
| Heat loss share | 5.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat required | 89.158 GJ |
| Steam | 43.190 t |
| Steam per OD tonne of wood | 0.86379 kg/kg |
Open this example in the calculator and change any input.
Formula
\(Q = \frac{(W c_w + M_l c_l)(T_2 - T_1)}{1 - \varepsilon}, \quad m_s = \frac{Q}{h_g - h_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | OD wood | kg |
| \(c_w\) | Wood specific heat | J/(kg·K) |
| \(M_l\) | Liquor and water (incl. chip water) | kg |
| \(c_l\) | Liquor specific heat | J/(kg·K) |
| \(T_1\) | Charge temperature | K |
| \(T_2\) | Cooking temperature | K |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(\text{heating}\) | Heating | - |
| \(\varepsilon\) | Heat loss share | - |
| \(Q\) | Heat required | J |
| \(m_s\) | Steam | kg |
| \(m_s/W\) | Steam per OD tonne of wood | kg/kg |
| \(h_g\) | Enthalpy of saturated steam at p_s (IAPWS-IF97) | J/kg |
| \(h_c\) | Condensate enthalpy: liquid at T_2 (direct) or saturated at p_s (indirect) | J/kg |
Method and standards
Sensible heat balance with IF97 steam enthalpies.
Where it is used
- Digester steam budgets.
- Comparing heating methods.
Common mistakes
- Forgetting chip water.
- Ignoring condensate dilution.
Assumptions and limits
- Uniform heating; constant specific heats.
- Direct steaming: the condensate stays and ends as liquid at the cooking temperature, h_c = h(p_s, T_2) from IAPWS-IF97. Indirect: the condensate leaves saturated at p_s.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 7–8 (digester heating, direct and indirect)
- Steam enthalpies from IAPWS-IF97
Questions and answers
Why does direct steaming use less steam?
The condensate stays in the digester and gives up its heat down to cooking temperature.
What specific heat for wood?
About 1.3–1.4 kJ/(kg·K) for dry wood.
What steam use is typical?
1–2 t of steam per OD tonne of wood for batch cooks without heat recovery.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.