Worked example
Example: 45 % to 92 %, 1.3 kg/kg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dryness entering the dryers | 45.000 % |
| Dryness at the reel | 92.000 % |
| Paper production | 1,000.0 t/d |
| Steam per kg of water evaporated | 1.3000 kg/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water evaporated per tonne | 1.0444 kg/kg |
| Steam per tonne of paper | 1.3578 kg/kg |
| Steam to the dryers | 56.574 t/h |
Open this example in the calculator and change any input.
Formula
\(E = \frac{d_{reel}}{d_{press}} - 1, \quad S = sE\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_{press}\) | Dryness entering the dryers | - |
| \(d_{reel}\) | Dryness at the reel | - |
| \(P\) | Paper production | kg/s |
| \(s\) | Steam per kg of water evaporated | kg/kg |
| \(E\) | Water evaporated per tonne | kg/kg |
| \(S\) | Steam per tonne of paper | kg/kg |
| \(\dot S\) | Steam to the dryers | kg/s |
Method and standards
Water balance with a specific steam consumption.
Where it is used
- Steam budgets and audits.
Common mistakes
- Ignoring steam to steam boxes and hood air heating.
Assumptions and limits
- s includes all dryer losses.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 17 (drying: steam-heated cylinders; steam per unit water evaporated)
Questions and answers
Why more than 1 kg of steam per kg of water?
Latent heat of steam roughly equals that of the evaporated water, plus sheet heating, hood air and losses.
What is typical?
1.3–1.6 t of steam per tonne of water evaporated; about 1.5–2.5 t per tonne of paper.
What improves it?
Higher press dryness, good condensate removal and a closed, humid hood.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.