Worked example
Example: 600 t/d ONP/OMG. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Recovered paper (as received) | 600.00 t/d |
| Moisture in recovered paper | 10.000 % |
| Ash in the recovered paper (dry) | 18.000 % |
| Ash in the deinked pulp (dry) | 4.0000 % |
| Fibre (ash-free) lost to rejects | 8.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry recovered paper | 540.00 t/d |
| Deinked pulp (dry) | 424.35 t/d |
| Yield on dry recovered paper | 78.583 % |
| Rejects and sludge (dry) | 115.65 t/d |
Open this example in the calculator and change any input.
Formula
\(\dot m_{OD} = \dot m_{RP}(1 - w), \quad \dot m_p = \frac{\dot m_{OD}(1 - a_{in})(1 - L_f)}{1 - a_{out}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{RP}\) | Recovered paper (as received) | kg/s |
| \(w\) | Moisture in recovered paper | - |
| \(a_{in}\) | Ash in the recovered paper (dry) | - |
| \(a_{out}\) | Ash in the deinked pulp (dry) | - |
| \(L_f\) | Fibre (ash-free) lost to rejects | - |
| \(\dot m_{OD}\) | Dry recovered paper | kg/s |
| \(\dot m_p\) | Deinked pulp (dry) | kg/s |
| \(Y\) | Yield on dry recovered paper | - |
| \(\dot m_s\) | Rejects and sludge (dry) | kg/s |
Method and standards
Ash-free fibre balance.
Where it is used
- Recovered paper purchasing.
- Sludge handling sizing.
Common mistakes
- Mixing wet and dry tonnes.
- Ignoring ash in the product.
Assumptions and limits
- Ash and fibre balances only.
- Ash leaving in the pulp cannot exceed the ash fed; inputs that would need more are rejected.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 14 (recycled fibre: deinking yield and losses)
Questions and answers
What yields are typical?
Newsprint deinking 75–85 %; tissue and fine paper deinking, with more ash removed, 60–70 %.
Why does ash lower yield?
Filler is washed and floated out with the ink to raise brightness.
Is the yield on dry basis?
Yes, dry deinked pulp per dry recovered paper.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.