Worked example
Example: 45 t/h water, 0.16 kg/kg exhaust. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water evaporated | 45.000 t/h |
| Supply air humidity (per kg dry air) | 15.000 g/kg |
| Exhaust air humidity (per kg dry air) | 160.00 g/kg |
| Pressure in the hood (absolute) | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry air exhausted | 310.34 t/h |
| Water vapour partial pressure in the exhaust | 20.733 kPa |
| Exhaust dew point | 60.839 °C |
Open this example in the calculator and change any input.
Formula
\(\dot m_a = \frac{\dot E}{Y_e - Y_s}, \quad p_v = \frac{P\,Y_e}{0.621945 + Y_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot E\) | Water evaporated | kg/s |
| \(Y_s\) | Supply air humidity (per kg dry air) | kg/kg |
| \(Y_e\) | Exhaust air humidity (per kg dry air) | kg/kg |
| \(P\) | Pressure in the hood (absolute) | Pa |
| \(\dot m_a\) | Dry air exhausted | kg/s |
| \(p_v\) | Water vapour partial pressure in the exhaust | Pa |
| \(T_{dp}\) | Exhaust dew point | K |
Method and standards
Water balance on the hood air.
Where it is used
- Hood and heat recovery design.
Common mistakes
- Using wet air flow as dry air.
- Ignoring air leaking into the hood.
Assumptions and limits
- All evaporated water leaves with the exhaust.
- Humidities are humidity ratios (kg water per kg dry air); the pressure is absolute.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 17 (drying: hood ventilation and heat recovery)
- Psychrometric humidity ratio Y = 0.621945 p_v/(P − p_v); saturation from IAPWS-IF97
Questions and answers
Why run the hood humid?
Less air carries the same water, so less air must be heated and exhausted.
What limits humidity?
Condensation dripping on the sheet if hood surfaces fall below the dew point.
Where does the exhaust heat go?
To heat recovery towers for supply air and process water.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.