Worked example
Example: 1000 t/d, 20 days. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wood use (oven-dry) | 1,000.0 t/d |
| Chip bulk density (OD per loose m³) | 160.00 kg/m³ |
| Days of storage | 20.000 d |
| Pile height | 25.000 m |
| Fill factor of the pile envelope | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Chips stored (OD) | 20,000 t |
| Pile volume (loose) | 125,000 m³ |
| Ground area | 8,333.3 m² |
Open this example in the calculator and change any input.
Formula
\(M = \dot m_w t, \quad V = \frac{M}{\rho_b}, \quad A = \frac{V}{H\phi}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_w\) | Wood use (oven-dry) | kg/s |
| \(\rho_b\) | Chip bulk density (OD per loose m³) | kg/m³ |
| \(t\) | Days of storage | s |
| \(H\) | Pile height | m |
| \(\phi\) | Fill factor of the pile envelope | - |
| \(M\) | Chips stored (OD) | kg |
| \(V\) | Pile volume (loose) | m³ |
| \(A\) | Ground area | m² |
Method and standards
Inventory and geometry.
Where it is used
- Woodyard design.
Common mistakes
- Using solid wood density for chips.
- Ignoring pile shape.
Assumptions and limits
- Uniform pile; no compaction.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 3 (wood and chip handling and storage)
Questions and answers
What bulk density do chips have?
About 140–200 kg of OD wood per loose cubic metre.
What is the fill factor?
Pile volume divided by height × area; about 1/3 for a cone and 0.5–0.8 for long flat-topped piles.
Why limit storage time?
Chips heat, lose yield and can self-ignite in tall piles.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.