FireCADCalc

Digester Blow Heat: Flash Steam Recovered

Flash steam released when a batch digester is blown from cooking temperature to the blow tank pressure, from liquor and pulp mass, by an IF97 heat balance.

Pulp and paperIAPWS-IF97 (water and steam)

Inputs

Examples: 200 t liquor + 25 t pulp from 170 °CBlow at 1.5 bar

Results

Blow steam is condensed in an accumulator to make hot water; recovering it saves a large part of the digester steam.

The steam enthalpy is on the IAPWS datum (water at 0.01 °C); the heat recoverable into an accumulator at T_w is m_f (h_g − h_f(T_w)), some 15 % less with hot water at 70–80 °C.

Temperature after the blow99.974°C
Flash steam27.648t
Enthalpy of the flash steam (above water at 0.01 °C)73.973GJ
Flash share of the liquor13.824%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 200 t liquor + 25 t pulp from 170 °C. The inputs, in the units selected above:

InputValue
Liquor and water blown200,000 kg
Pulp blown (OD)25,000 kg
Fibre specific heat1.3400 kJ/(kg·K)
Cooking temperature170.00 °C
Blow tank pressure (absolute)101.33 kPa

Applying the formula below gives:

ResultValue
Temperature after the blow99.974 °C
Flash steam27.648 t
Enthalpy of the flash steam (above water at 0.01 °C)73.973 GJ
Flash share of the liquor13.824 %

Open this example in the calculator and change any input.

Formula

\(m_f = \frac{M\,[h_f(T_1) - h_f(p_2)] + M_f c_f (T_1 - T_2)}{h_{fg}(p_2)}\)

Variables

Symbol Meaning SI unit
\(M\) Liquor and water blown kg
\(M_f\) Pulp blown (OD) kg
\(c_f\) Fibre specific heat J/(kg·K)
\(T_1\) Cooking temperature K
\(p_2\) Blow tank pressure (absolute) Pa
\(T_2\) Temperature after the blow K
\(m_f\) Flash steam kg
\(Q\) Enthalpy of the flash steam (above water at 0.01 °C) J
\(m_f/M\) Flash share of the liquor -

Method and standards

Adiabatic flash heat balance.

Where it is used

  • Batch digester heat recovery design.

Common mistakes

  • Ignoring the fibre's heat.
  • Using gauge blow tank pressure.

Assumptions and limits

  • Liquor as water (no boiling-point rise), so the real flash is somewhat lower; no heat loss.
  • Q is the steam enthalpy on the IAPWS datum (liquid water at 0.01 °C). The heat an accumulator can recover to hot water at T_w is m_f [h_g − h_f(T_w)], about 15 % less for water at 70–80 °C.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 8.5 (blow heat recovery)
  • Steam and water enthalpies from IAPWS-IF97 (liquor treated as water)

Questions and answers

Why is so much steam released?

The charge is above 100 °C; dropping to the blow tank pressure flashes the excess heat into steam.

Is black liquor treated as water?

Yes; dissolved solids lower the flash a little.

Where does the heat go?

Into an accumulator of hot water used for washing and process heating.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators