FireCADCalc

Fillet Weld Group under Eccentric Load: Throat Shear Stress

Primary and secondary throat shear and the resultant at the critical point of a fillet weld group under an eccentric load, by the treat-the-weld-as-a-line method.

Inputs

Examples: Illustrative: two horizontal 100 mm welds, 8 mm leg, 150 mm apart, 40 kN at 200 mmTwo vertical 200 mm welds 120 mm apart, 6 mm leg, 25 kN at 250 mmAll-round box 150 x 250, 10 mm leg, 100 kN at 300 mmSingle vertical 120 mm weld, 8 mm leg, 5 kN at 50 mm

Accepted: 0 to 5,000 mm
Accepted: 1 to 5,000 mm
Accepted: 1 to 50 mm
Accepted: 0.001 to 100,000 kN
Accepted: 0 to 10,000 mm
Accepted: 1 to 1,000 MPa

Results

Elastic vector method: direct shear F/A on the throat plus torsional shear Mr/J, with J = 0.707h J_u; the resultant is checked at the corner farthest from the centroid on the load side. Weld returns and end effects are ignored.

Throat area 0.707 h × total length1,131.2mm²
Unit polar moment of the weld lines129,167cm⁴
Primary (direct) shear35.361MPa
Secondary (torsional) shear at the farthest point98.706MPa
Resultant shear at the critical point121.92MPa
Factor of safety on the allowable0.90221

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: two horizontal 100 mm welds, 8 mm leg, 150 mm apart, 40 kN at 200 mm. The inputs, in the units selected above:

InputValue
Weld patternTwo horizontal lines b, spaced d
Horizontal dimension100.00 mm
Vertical dimension150.00 mm
Fillet leg size8.0000 mm
Vertical load40.000 kN
Eccentricity of the load from the weld group centroid200.00 mm
Allowable throat shear stress110.00 MPa

Applying the formula below gives:

ResultValue
Throat area 0.707 h × total length1,131.2 mm²
Unit polar moment of the weld lines129,167 cm⁴
Primary (direct) shear35.361 MPa
Secondary (torsional) shear at the farthest point98.706 MPa
Resultant shear at the critical point121.92 MPa
Factor of safety on the allowable0.90221

Open this example in the calculator and change any input.

Formula

\(\tau' = \frac{F}{A}, \quad \tau'' = \frac{Fe\,r}{J}, \quad J = 0.707hJ_u, \quad \tau = \sqrt{\left(\tau' + \frac{Fe\,r_x}{J}\right)^2 + \left(\frac{Fe\,r_y}{J}\right)^2}\)

\(J_u = \frac{d(3b^2 + d^2)}{6}\ \text{(two vertical)}, \quad \frac{b(3d^2 + b^2)}{6}\ \text{(two horizontal)}, \quad \frac{(b + d)^3}{6}\ \text{(box)}\)

Variables

Symbol Meaning SI unit
\(\text{pattern}\) Weld pattern -
\(b\) Horizontal dimension m
\(d\) Vertical dimension m
\(h\) Fillet leg size m
\(F\) Vertical load N
\(e\) Eccentricity of the load from the weld group centroid m
\(\tau_{allow}\) Allowable throat shear stress Pa
\(A\) Throat area 0.707 h × total length m²
\(J_u\) Unit polar moment of the weld lines m⁴
\(\tau'\) Primary (direct) shear Pa
\(\tau''\) Secondary (torsional) shear at the farthest point Pa
\(\tau\) Resultant shear at the critical point Pa
\(n\) Factor of safety on the allowable -

Method and standards

Elastic analysis of eccentrically loaded weld groups.

Where it is used

  • Brackets, gussets and lifting lugs.
  • Machine frames and structural connections (preliminary).

Common mistakes

  • Using the leg instead of the throat.
  • Taking the eccentricity from the column face instead of the weld centroid.

Assumptions and limits

  • Elastic, rigid connected parts, uniform weld size, load in the plane of the group.

References

  • Weld group treated as lines: direct and torsional throat shear

Questions and answers

Why treat the weld as a line?

The throat is thin compared with the group, so computing J_u for lines and multiplying by the throat 0.707h is accurate and simple.

Is the elastic method conservative?

Yes; the instantaneous-centre (ultimate strength) method used by steel design codes gives higher capacities for the same group.

What do the defaults represent?

An illustrative bracket welded by two horizontal 100 mm fillet welds of 8 mm leg spaced 150 mm, carrying 40 kN at 200 mm eccentricity.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Budynas and Nisbett, Shigley's Mechanical Engineering Design, 9th ed. (McGraw-Hill, 2011), sec. 9-4, Table 9-1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.