Worked example
Example: 30 mPa·s, 1 500 rpm, 50 mm journal, 50 mm long, 40 µm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil viscosity at the running temperature | 30.000 mPa·s |
| Journal speed | 1,500.0 rpm |
| Journal radius | 25.000 mm |
| Bearing length | 50.000 mm |
| Radial clearance | 40.000 µm |
| Radial load | 2.0000 kN |
Applying the formula below gives:
| Result | Value |
|---|---|
| Friction torque 4π² μ N r³ l / c | 0.57830 N·m |
| Friction coefficient T/(W r) | 0.011566 |
| Power lost | 90.839 W |
| Bearing pressure W/(2 r l) | 800.00 kPa |
Open this example in the calculator and change any input.
Formula
\(T = \frac{4\pi^2 \mu N r^3 l}{c}, \quad f = \frac{T}{W r}, \quad P = 2\pi N T\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\mu\) | Oil viscosity at the running temperature | Pa·s |
| \(N\) | Journal speed | 1/s |
| \(r\) | Journal radius | m |
| \(l\) | Bearing length | m |
| \(c\) | Radial clearance | m |
| \(W\) | Radial load | N |
| \(T\) | Friction torque 4π² μ N r³ l / c | N·m |
| \(f\) | Friction coefficient T/(W r) | - |
| \(P\) | Power lost | W |
| \(p\) | Bearing pressure W/(2 r l) | Pa |
Method and standards
Viscous shear in a concentric film.
Where it is used
- Bearing heat and oil flow estimates.
- Machine design examinations.
Common mistakes
- Diameter instead of radius.
- Viscosity at the wrong temperature.
Assumptions and limits
- Concentric journal, full film. Valid for lightly loaded bearings only: check the Sommerfeld number S = (r/c)² μN/p; for loaded bearings use the Raimondi–Boyd charts, which give a higher friction.
References
- N. Petroff (1883); Shigley's Mechanical Engineering Design (Budynas and Nisbett)
- ch. 12
Questions and answers
50 mm journal, 50 mm long, 40 µm clearance, 30 mPa·s oil, 1500 rpm?
Torque 0.578 N·m, loss 91 W.
Why does clearance matter?
Friction rises as clearance falls; too much clearance lowers load capacity.
What viscosity?
At the oil film temperature, much lower than at 40 °C.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.