FireCADCalc

Springs in Series and Parallel: Equivalent Rate

Equivalent stiffness of up to three springs in series or in parallel, the deflection under a load and the load carried by each spring.

Inputs

Examples: 20 and 30 N/mm in parallel, 1 kNSame pair in series (third very stiff)Three in series 10, 20, 40 N/mm, 500 NTwo in series, no third spring (k3 = 0)

Results

Equivalent rate50.000N/mm
Deflection under the load20.000mm
Load on spring 10.40000kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 and 30 N/mm in parallel, 1 kN. The inputs, in the units selected above:

InputValue
Rate of spring 120.000 N/mm
Rate of spring 230.000 N/mm
Rate of spring 3 (0 if there is no third spring)0 N/mm
ArrangementParallel (side by side)
Load1.0000 kN

Applying the formula below gives:

ResultValue
Equivalent rate50.000 N/mm
Deflection under the load20.000 mm
Load on spring 10.40000 kN

Open this example in the calculator and change any input.

Formula

\(k_{par} = \sum k_i, \quad \frac{1}{k_{ser}} = \sum \frac{1}{k_i}\)

Variables

Symbol Meaning SI unit
\(k_1\) Rate of spring 1 N/m
\(k_2\) Rate of spring 2 N/m
\(k_3\) Rate of spring 3 (0 if there is no third spring) N/m
\(\text{arr}\) Arrangement -
\(F\) Load N
\(k\) Equivalent rate N/m
\(\delta\) Deflection under the load m
\(F_1\) Load on spring 1 N

Method and standards

Equal deflection (parallel) or equal force (series).

Where it is used

  • Spring packs and mounts.
  • Vibration isolation.

Common mistakes

  • Swapping the rules.
  • Ignoring preload differences.

Assumptions and limits

  • Linear springs; k₃ = 0 means there is no third spring, in either arrangement.

References

  • Hooke's law for combined springs

Questions and answers

20 and 30 N/mm in parallel?

50 N/mm; 1 kN deflects them 20 mm.

And in series?

12 N/mm: the softer spring dominates.

Where is it used?

Nested valve springs, mounts and supports in series with a frame.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.