Worked example
Example: M20, As 245 mm², proof 600 MPa, 75 %, K 0.2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Nominal bolt diameter | 20.000 mm |
| Tensile stress area | 245.00 mm² |
| Proof strength of the bolt | 600.00 MPa |
| Preload as a share of proof load | 75.000 % |
| Nut factor | 0.20000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tightening torque | 441.00 N·m |
| Bolt preload | 110.25 kN |
| Proof load | 147.00 kN |
| Tensile stress at preload | 450.00 MPa |
Open this example in the calculator and change any input.
Formula
\(F_p = S_p\,A_s \qquad F_i = x\,F_p \qquad T = K\,F_i\,d \qquad \sigma_i = x\,S_p\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d\) | nominal diameter | m |
| \(A_s\) | tensile stress area | m² |
| \(S_p\) | proof strength | Pa |
| \(x\) | preload share of proof load | – |
| \(K\) | nut factor | – |
| \(T\) | tightening torque | N·m |
| \(F_i\) | preload | N |
| \(F_p\) | proof load | N |
| \(\sigma_i\) | stress at preload | Pa |
Method and standards
Short-form torque–tension relation with an empirical nut factor.
Where it is used
- Flange and pressure-part bolting.
- Structural and machine joints.
- Maintenance torque charts.
Common mistakes
- Using a nut factor for dry threads on lubricated bolts.
- Using nominal area instead of stress area.
- Expecting better than ±25 % preload from torque.
Assumptions and limits
- Nut factor scatter dominates; for critical joints use tension control.
- The combined (tension plus thread torsion) stress during tightening is not checked; a preload above 90 % of proof load is flagged.
References
- Short-form torque equation T = K F d
Questions and answers
What torque for an M20 bolt with 600 MPa proof strength at 75 % preload?
Preload 110 kN; torque 441 N·m with K = 0.2.
Why does lubrication matter so much?
Most torque goes into friction; lowering K from 0.2 to 0.15 gives a third more preload at the same torque.
Where do I get the stress area?
From the thread standard's table for the size and pitch.