Worked example
Example: 6 m span, 10 kN/m + 20 kN, steel beam I 8 603 cm⁴, Z 573.6 cm³. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Span | 6.0000 m |
| Uniformly distributed load (including self weight) | 10.000 kN/m |
| Point load at mid-span | 20.000 kN |
| Modulus of elasticity | 200.00 GPa |
| Second moment of area | 8,603.0 cm⁴ |
| Elastic section modulus | 573.60 cm³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Maximum bending moment (mid-span) | 75.000 kN·m |
| Mid-span deflection | 15.038 mm |
| Maximum bending stress | 130.75 MPa |
| Each support reaction | 40.000 kN |
| Span over deflection | 398.98 |
Open this example in the calculator and change any input.
Formula
\(R = \frac{wL + P}{2} \qquad M_{max} = \frac{wL^2}{8} + \frac{PL}{4} \qquad \delta_{max} = \frac{5wL^4}{384EI} + \frac{PL^3}{48EI} \qquad \sigma_b = \frac{M_{max}}{Z}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | span | m |
| \(w\) | distributed load | N/m |
| \(P\) | central point load | N |
| \(E\) | modulus of elasticity | Pa |
| \(I\) | second moment of area | m⁴ |
| \(Z\) | section modulus | m³ |
| \(M_{max}\) | maximum moment | N·m |
| \(\delta_{max}\) | mid-span deflection | m |
| \(\sigma_b\) | bending stress | Pa |
| \(R\) | each reaction | N |
| \(L/\delta\) | span over deflection | – |
Method and standards
Euler–Bernoulli small-deflection theory, superposing the uniform and central point load cases.
Where it is used
- Pipe rack and platform beams.
- Monorail and lifting beams (with dynamic factors).
- Equipment supports.
Common mistakes
- Leaving out self weight.
- Mixing cm⁴ and mm⁴.
- Ignoring lateral-torsional buckling.
Assumptions and limits
- Linear elastic, small deflection; shear and buckling checked separately.
- The bending stress is not compared with an allowable stress: check it against your design code.
References
- Euler–Bernoulli beam theory
Questions and answers
What does a 6 m beam with 10 kN/m and a 20 kN centre load do?
75 kN·m at mid-span, 15.0 mm deflection (span/399) and 131 MPa bending stress with I 8603 cm⁴, Z 573.6 cm³.
Where do I get I and Z?
From the section tables of your steel standard, or calculate them for the shape.
What deflection is acceptable?
Your design code sets it; span/250 to span/360 are common for floors and pipe racks.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.