Worked example
Example: Steel, I 100 cm⁴, A 20 cm², 3 m, pinned. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Modulus of elasticity | 200.00 GPa |
| Least second moment of area of the section | 100.00 cm⁴ |
| Cross-section area | 2,000.0 mm² |
| Yield strength (0 = not checked) | 0 MPa |
| Column length | 3.0000 m |
| End condition (effective length factor) | Pinned at both ends (K = 1) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical buckling load | 219.32 kN |
| Critical stress | 109.66 MPa |
| Least radius of gyration | 22.361 mm |
| Effective length K L | 3.0000 m |
| Slenderness ratio | 134.16 |
Open this example in the calculator and change any input.
Formula
\(P_{cr} = \frac{\pi^2 E I}{(K L)^2}, \quad \sigma_{cr} = \frac{P_{cr}}{A}\)
\(r = \sqrt{I / A}, \quad L_e = K L, \quad \lambda = L_e / r\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E\) | Modulus of elasticity | Pa |
| \(I\) | Least second moment of area of the section | m⁴ |
| \(A\) | Cross-section area | m² |
| \(\sigma_y\) | Yield strength (0 = not checked) | Pa |
| \(L\) | Column length | m |
| \(K\) | End condition (effective length factor) | - |
| \(P_{cr}\) | Critical buckling load | N |
| \(\sigma_{cr}\) | Critical stress | Pa |
| \(r\) | Least radius of gyration | m |
| \(L_e\) | Effective length K L | m |
| \(L_e / r\) | Slenderness ratio | - |
Method and standards
Euler's elastic buckling load for an ideal straight column; the effective length factor K gives the theoretical values for the classic end conditions.
Where it is used
- Checking struts, props, pump columns and pipe supports.
- Comparing sections for a column.
- Teaching and first checks.
Common mistakes
- Using the larger I instead of the least one.
- Taking practical end fixity as fully fixed.
- Using Euler for short columns.
Assumptions and limits
- Elastic, perfectly straight, centrally loaded column.
- No safety factor applied.
- With a yield strength entered, a critical stress at or above it is flagged.
- Theoretical K values. Design practice uses larger recommended values for imperfect fixity (for example 0.65 fixed–fixed, 0.80 fixed–pinned and 2.1 fixed–free).
References
- L. Euler (1757); effective length factors (Timoshenko and Gere, Theory of Elastic Stability)
Questions and answers
What load buckles a 3 m pinned steel column with I = 100 cm⁴?
π²EI/L² = 219 kN; on a 20 cm² section that is 110 MPa.
How do the ends change it?
Through the effective length KL: 2 for a cantilever (a quarter of the pinned load), 0.699 fixed–pinned, 0.5 fixed–fixed (four times).
When does Euler not apply?
When the critical stress approaches yield, as in short stocky columns; then a Johnson or design-code column curve governs.