FireCADCalc

Wire Rope Tension and Bending Stress (Reuleaux)

Direct tensile stress, bending stress over a sheave by Reuleaux's formula and the static factor of safety of a wire rope from load, rope size and sheave diameter.

Inputs

Examples: 50 kN, 20 mm rope, 600 mm sheaveHoist 12 kN, 12 mm, 300 mmCrane 120 kN, 32 mm, 1.0 m

About 0.4 to 0.6 by construction; from the rope maker.

Results

Use n = F_u/(W + F_b) for static and bending checks of stationary or general hoisting ropes. Shigley's n_s = (F_u − F_b)/W is higher and belongs with Shigley's fatigue-adjusted design factors for high-speed mine or elevator hoisting; do not judge it against the limits used for n.

Lifting codes set minimum factors of safety and D/d ratios for each duty; this is a static check only.

Metallic area157.08mm²
Direct tensile stress W/A318.31MPa
Bending stress E_r d_w/D179.83MPa
Equivalent bending load σ_b A28.248kN
Factor of safety F_u/(W + F_b): use this one3.3228
Shigley form (F_u − F_b)/W, only with Shigley's design factors4.6350

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 kN, 20 mm rope, 600 mm sheave. The inputs, in the units selected above:

InputValue
Load on the rope (including hook and rope weight)50.000 kN
Rope diameter20.000 mm
Metallic area as a share of the circle πd²/450.000 %
Outer wire diameter1.3000 mm
Sheave pitch diameter600.00 mm
Modulus of the rope83.000 GPa
Minimum breaking force of the rope260.00 kN

Applying the formula below gives:

ResultValue
Metallic area157.08 mm²
Direct tensile stress W/A318.31 MPa
Bending stress E_r d_w/D179.83 MPa
Equivalent bending load σ_b A28.248 kN
Factor of safety F_u/(W + F_b): use this one3.3228
Shigley form (F_u − F_b)/W, only with Shigley's design factors4.6350

Open this example in the calculator and change any input.

Formula

\(\sigma_t = \frac{W}{A_m}, \quad \sigma_b = \frac{E_r d_w}{D}, \quad n = \frac{F_u}{W + \sigma_b A_m}, \quad n_s = \frac{F_u - F_b}{W}\)

Variables

Symbol Meaning SI unit
\(W\) Load on the rope (including hook and rope weight) N
\(d_r\) Rope diameter m
\(A_m\) Metallic area as a share of the circle πd²/4 -
\(d_w\) Outer wire diameter m
\(D\) Sheave pitch diameter m
\(E_r\) Modulus of the rope Pa
\(F_u\) Minimum breaking force of the rope N
\(A\) Metallic area m²
\(\sigma_t\) Direct tensile stress W/A Pa
\(\sigma_b\) Bending stress E_r d_w/D Pa
\(F_b\) Equivalent bending load σ_b A N
\(n\) Factor of safety F_u/(W + F_b), the one to use -
\(n_s\) Shigley form (F_u − F_b)/W, only with Shigley's design factors -

Method and standards

Reuleaux bending stress of wires over a sheave.

Where it is used

  • Hoists and cranes.
  • Machine design examinations.

Common mistakes

  • Using rope diameter for wire diameter.
  • Ignoring rope weight on long lifts.
  • Judging Shigley's n_s against the limits meant for n; n_s is always the higher of the two.

Assumptions and limits

  • Shigley defines the static factor as n_s = (F_u − F_b)/F_t, with F_t the rope tension (W here); it is shown as n_s. The factor n = F_u/(W + F_b) adds the bending load to the tension instead of subtracting it from the strength, and gives a lower (more conservative) figure. Use n for static and bending checks of stationary or general hoisting ropes (50 kN on a 20 mm rope over a 600 mm sheave: n = 3.32). Use n_s (4.63 for the same case) only when working with Shigley's fatigue-adjusted design factors for dynamic, high-speed mine or elevator hoisting.

  • Static load.

References

  • Shigley's Mechanical Engineering Design (Budynas and Nisbett)
  • ch. 17 (wire rope, bending stress σ_b = E_r d_w / D)

Questions and answers

What does bending over a 600 mm sheave add for 1.3 mm wires?

180 MPa, equal to 28 kN of extra load on a 20 mm rope.

Why big sheaves?

Bending stress falls as the sheave grows, and fatigue life rises sharply.

Is the static factor enough?

No: fatigue and wear govern rope life; lifting codes set the factors.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.