Fillet Weld Metal and Electrode Consumption

Weld metal mass of a fillet weld from leg length, length and reinforcement, and the electrodes or wire needed from the deposition efficiency.

Thermal power plantProcess steam and utilities

Inputs

Examples: 8 mm fillet, 50 m6 mm fillet, 20 m, MIG wire

Your figure: about 0.55–0.65 for stick electrodes with stub loss, 0.9–0.95 for solid wire.

Results

Weld cross-section36.800mm²
Weld metal deposited14.444kg
Consumables needed24.073kg
Electrodes (rounded up)803.00

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 mm fillet, 50 m. The inputs, in the units selected above:

InputValue
Leg length z (not the throat; throat a = 0.707 z)8.0000 mm
Weld length50.000 m
Reinforcement allowance (share of the triangle)15.000 %
Weld metal density7,850.0 kg/m³
Deposition efficiency (deposited / consumed)60.000 %
Mass of one electrode (0 for wire)30.000 g

Applying the formula below gives:

ResultValue
Weld cross-section36.800 mm²
Weld metal deposited14.444 kg
Consumables needed24.073 kg
Electrodes (rounded up)803.00

Open this example in the calculator and change any input.

Formula

\(A = \frac{z^2}{2}(1 + k_r), \quad m_w = A L \rho, \quad m_c = \frac{m_w}{\eta_d}\)

Variables

Symbol Meaning SI unit
\(z\) Leg length z (not the throat; throat a = 0.707 z) m
\(L\) Weld length m
\(k_r\) Reinforcement allowance (share of the triangle) -
\(\rho\) Weld metal density kg/m³
\(\eta_d\) Deposition efficiency (deposited / consumed) -
\(m_e\) Mass of one electrode (0 for wire) kg
\(A\) Weld cross-section m²
\(m_w\) Weld metal deposited kg
\(m_c\) Consumables needed kg
\(N_e\) Electrodes (rounded up) -

Method and standards

Geometry.

Where it is used

  • Fabrication estimates.
  • Boiler and structural welding.

Common mistakes

  • Throat used as leg.
  • Ignoring stub loss.

Assumptions and limits

  • Equal-leg fillet. Enter the leg length; a throat size a corresponds to a leg of a/0.707 (entering the throat as the leg understates the weld metal by half).

References

  • Triangle area z²/2 with reinforcement; consumables = deposit / deposition efficiency

Questions and answers

8 mm fillet, 50 m, 15 % reinforcement?

14.4 kg of weld metal; 24.1 kg of electrodes at 60 %.

Why does leg size matter so much?

Weld metal grows with the square of the leg: a 10 mm fillet has 56 % more than 8 mm.

Unequal legs?

Use the mean of the two legs squared, or the true triangle area.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.