Worked example
Example: 12 mm plate, 60°. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plate thickness | 12.000 mm |
| Included groove angle | 60.000 ° |
| Root gap | 2.0000 mm |
| Root face | 1.5000 mm |
| Reinforcement allowance (share of the groove) | 10.000 % |
| Weld length | 20.000 m |
| Weld metal density | 7,850.0 kg/m³ |
| Deposition efficiency | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Weld cross-section | 96.418 mm² |
| Weld metal deposited | 15.138 kg |
| Consumables needed | 25.229 kg |
Open this example in the calculator and change any input.
Formula
\(A = \left[g t + (t - f)^2\tan\frac{\alpha}{2}\right](1 + k_r)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t\) | Plate thickness | m |
| \(\alpha\) | Included groove angle | rad |
| \(g\) | Root gap | m |
| \(f\) | Root face | m |
| \(k_r\) | Reinforcement allowance (share of the groove) | - |
| \(L\) | Weld length | m |
| \(\rho\) | Weld metal density | kg/m³ |
| \(\eta_d\) | Deposition efficiency | - |
| \(A\) | Weld cross-section | m² |
| \(m_w\) | Weld metal deposited | kg |
| \(m_c\) | Consumables needed | kg |
Method and standards
Geometry.
Where it is used
- Fabrication and pipe welding estimates.
- Comparing joint preparations.
Common mistakes
- Half angle vs included angle.
- Ignoring the root gap.
Assumptions and limits
- Single-V, no backing.
References
- Groove geometry: root gap rectangle plus the two bevel triangles
- (t − f)² tan(α/2)
Questions and answers
12 mm plate, 60°, 2 mm gap, 1.5 mm face?
About 96 mm²: 15.1 kg over 20 m.
Narrower angle?
Saves metal but needs access for the torch and fusion of the side walls.
Double-V?
For thick plate a double-V roughly halves the weld metal.