FireCADCalc

Welding Heat Input and Arc Energy (kJ/mm)

Arc energy and heat input of a weld run from voltage, current and travel speed, with the process thermal efficiency factor, in kJ/mm.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalBoiler

Inputs

Examples: SMAW 28 V, 250 A, 300 mm/min, k 1 (arc energy)SAW 32 V, 600 A, 500 mm/min, k 1GTAW 12 V, 150 A, 100 mm/min, k 0.6

1 gives the arc energy. For heat input use the factor your welding code gives for the process (EN ISO 1011-1 / ISO/TR 17671-1).

Results

Heat input (kJ/mm)1.4000
Arc energy (kJ/mm)1.4000
Heat input (kJ/in)35.560

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: SMAW 28 V, 250 A, 300 mm/min, k 1 (arc energy). The inputs, in the units selected above:

InputValue
Arc voltage28.000 V
Welding current250.00 A
Travel speed300.00 mm/min
Thermal efficiency factor of the process100.00 %

Applying the formula below gives:

ResultValue
Heat input (kJ/mm)1.4000
Arc energy (kJ/mm)1.4000
Heat input (kJ/in)35.560

Open this example in the calculator and change any input.

Formula

\(E = \frac{U\,I}{v} \qquad Q = k\,E\)

Variables

Symbol Meaning SI unit
\(U\) arc voltage V
\(I\) welding current A
\(v\) travel speed m/s
\(k\) thermal efficiency factor –
\(Q\) heat input kJ/mm
\(E\) arc energy kJ/mm
\(Q_{in}\) heat input kJ/in

Method and standards

Arc energy and heat input as defined in EN ISO 1011-1 and ISO/TR 17671-1.

Where it is used

  • Writing and checking WPS limits.
  • Toughness-critical welds.
  • Preheat calculations.

Common mistakes

  • Using wire feed speed for travel speed.
  • Averaging voltage of pulsed processes.
  • Applying the wrong efficiency factor.

Assumptions and limits

  • Steady arc; for pulsed processes use instantaneous energy.
  • With the default k = 1 the heat input equals the arc energy; enter the process factor (for example about 0.8 for GMAW) to report heat input.

References

  • EN ISO 1011-1 / ISO/TR 17671-1 (arc energy and heat input)

Questions and answers

What is the arc energy at 28 V, 250 A and 300 mm/min?

1.4 kJ/mm (35.6 kJ/in).

Arc energy or heat input?

Heat input is arc energy times the process thermal efficiency factor from your code; enter 1 for arc energy.

Why does heat input matter?

It sets cooling rate: too low risks hardness and cracking, too high lowers toughness.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...