FireCADCalc

Weld Cooling Time t8/5 (Rosenthal Thick and Thin Plate)

Weld cooling time from 800 to 500 °C by Rosenthal's thick-plate (3-D) and thin-plate (2-D) solutions, the transition thickness and which one governs.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 1.5 kJ/mm on 15 mm, no preheat2.5 kJ/mm on 8 mm, 150 °C preheat

A plain number in MJ/(m³·K); about 5 for steel.

Results

Rosenthal's point and line sources with constant properties. Real joints cool somewhat differently; empirical shape factors (fillet, T-joint) correct for joint geometry. Longer t8/5 gives softer, tougher HAZ; very short t8/5 gives hard martensite.

Thick-plate t8/56.3764s
Thin-plate t8/514.306s
Transition thickness22.468mm
Governing t8/514.306s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.5 kJ/mm on 15 mm, no preheat. The inputs, in the units selected above:

InputValue
Net heat input1.5000 kJ/mm
Preheat or plate temperature20.000 °C
Plate thickness15.000 mm
Thermal conductivity of steel (500–800 °C)30.000 W/(m·K)
Volumetric heat capacity (MJ/(m³·K))5.0000 -

Applying the formula below gives:

ResultValue
Thick-plate t8/56.3764 s
Thin-plate t8/514.306 s
Transition thickness22.468 mm
Governing t8/514.306 s

Open this example in the calculator and change any input.

Formula

\(t_{8/5,3D} = \frac{Q}{2\pi k}\left(\frac{1}{500 - T_0} - \frac{1}{800 - T_0}\right), \quad t_{8/5,2D} = \frac{(Q/d)^2}{4\pi k\rho c}\left[\frac{1}{(500 - T_0)^2} - \frac{1}{(800 - T_0)^2}\right]\)

Variables

Symbol Meaning SI unit
\(Q\) Net heat input (kJ/mm) -
\(T_0\) Preheat or plate temperature K
\(d\) Plate thickness m
\(k\) Thermal conductivity of steel (500–800 °C) W/(m·K)
\(\rho c\) Volumetric heat capacity (MJ/(m³·K)) -
\(t_{8/5,3D}\) Thick-plate t8/5 s
\(t_{8/5,2D}\) Thin-plate t8/5 s
\(d_t\) Transition thickness m
\(t_{8/5}\) Governing t8/5 s

Method and standards

Rosenthal solutions.

Where it is used

  • Welding procedure design.
  • Predicting HAZ hardness trends.

Common mistakes

  • Using arc energy instead of net heat input.
  • Using the thick-plate result on thin plate.

Assumptions and limits

  • Constant properties; bead-on-plate. Pure Rosenthal solutions without the empirical joint factors of codes such as EN 1011-2, whose t₈/₅ values differ.
  • Q (kJ/mm) and ρc (MJ/(m³·K)) are plain numbers in every unit system; divide kJ/in by 25.4.

References

  • Rosenthal (1946) moving point and line heat source solutions (Kou, Welding Metallurgy, 2nd ed., ch. 2)

Questions and answers

Why does t8/5 matter?

Austenite transforms between 800 and 500 °C in steels; the time spent there decides HAZ hardness and toughness.

What is the transition thickness?

Below it, heat flows in two dimensions (thin plate) and cooling is slower than the thick-plate formula predicts.

What do the defaults represent?

A 1.5 kJ/mm weld on 15 mm steel without preheat.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.