Worked example
Example: 1.5 kJ/mm on 15 mm, no preheat. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Net heat input | 1.5000 kJ/mm |
| Preheat or plate temperature | 20.000 °C |
| Plate thickness | 15.000 mm |
| Thermal conductivity of steel (500–800 °C) | 30.000 W/(m·K) |
| Volumetric heat capacity (MJ/(m³·K)) | 5.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thick-plate t8/5 | 6.3764 s |
| Thin-plate t8/5 | 14.306 s |
| Transition thickness | 22.468 mm |
| Governing t8/5 | 14.306 s |
Open this example in the calculator and change any input.
Formula
\(t_{8/5,3D} = \frac{Q}{2\pi k}\left(\frac{1}{500 - T_0} - \frac{1}{800 - T_0}\right), \quad t_{8/5,2D} = \frac{(Q/d)^2}{4\pi k\rho c}\left[\frac{1}{(500 - T_0)^2} - \frac{1}{(800 - T_0)^2}\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Net heat input (kJ/mm) | - |
| \(T_0\) | Preheat or plate temperature | K |
| \(d\) | Plate thickness | m |
| \(k\) | Thermal conductivity of steel (500–800 °C) | W/(m·K) |
| \(\rho c\) | Volumetric heat capacity (MJ/(m³·K)) | - |
| \(t_{8/5,3D}\) | Thick-plate t8/5 | s |
| \(t_{8/5,2D}\) | Thin-plate t8/5 | s |
| \(d_t\) | Transition thickness | m |
| \(t_{8/5}\) | Governing t8/5 | s |
Method and standards
Rosenthal solutions.
Where it is used
- Welding procedure design.
- Predicting HAZ hardness trends.
Common mistakes
- Using arc energy instead of net heat input.
- Using the thick-plate result on thin plate.
Assumptions and limits
- Constant properties; bead-on-plate. Pure Rosenthal solutions without the empirical joint factors of codes such as EN 1011-2, whose t₈/₅ values differ.
- Q (kJ/mm) and ρc (MJ/(m³·K)) are plain numbers in every unit system; divide kJ/in by 25.4.
References
- Rosenthal (1946) moving point and line heat source solutions (Kou, Welding Metallurgy, 2nd ed., ch. 2)
Questions and answers
Why does t8/5 matter?
Austenite transforms between 800 and 500 °C in steels; the time spent there decides HAZ hardness and toughness.
What is the transition thickness?
Below it, heat flows in two dimensions (thin plate) and cooling is slower than the thick-plate formula predicts.
What do the defaults represent?
A 1.5 kJ/mm weld on 15 mm steel without preheat.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.