FireCADCalc

Gearbox Selection: Ratio, Output Torque and Service Factor

Ratio, output torque and design (catalogue) torque and power of a gear reducer from motor power and speeds, gearbox efficiency and a service factor for the duty.

Inputs

Examples: Illustrative 7.5 kW to 50 rpmConveyor drive 22 kWWorm box, heavy shock

Accepted: 0.01 to 10,000 kW
Accepted: 9.5493 to 9,549.3 rpm
Accepted: 0.095493 to 9,549.3 rpm
Accepted: 30 to 100 %
About 1.0 for uniform load and 8–10 h a day, 1.25–1.5 for moderate shock or 24 h duty, 1.75–2 for heavy shock.Accepted: 0.8 to 3

Results

The ratio is input over output speed; output torque is the motor power, less gearbox losses, divided by the output speed. Catalogue ratings assume uniform load and moderate hours, so the selection torque is multiplied by a service factor for the actual load (uniform, moderate or heavy shock), starts per hour and daily running hours. Also check thermal rating for continuous duty and overhung loads on the shafts.

Ratio29.000
Output torque1,346.5N·m
Design (catalogue) torque2,019.7N·m
Design power11.250kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 7.5 kW to 50 rpm. The inputs, in the units selected above:

InputValue
Motor power7.5000 kW
Input (motor) speed1,450.0 rpm
Output speed wanted50.000 rpm
Gearbox efficiency94.000 %
Service factor for the load and hours1.5000 -

Applying the formula below gives:

ResultValue
Ratio29.000
Output torque1,346.5 N·m
Design (catalogue) torque2,019.7 N·m
Design power11.250 kW

Open this example in the calculator and change any input.

Formula

\(i = \frac{n_1}{n_2}, \quad T_2 = \frac{P\eta}{\omega_2}, \quad T_d = SF\cdot T_2\)

Variables

Symbol Meaning SI unit
\(P\) Motor power W
\(n_1\) Input (motor) speed rad/s
\(n_2\) Output speed wanted rad/s
\(\eta\) Gearbox efficiency -
\(SF\) Service factor for the load and hours -
\(i\) Ratio -
\(T_2\) Output torque N·m
\(T_d\) Design (catalogue) torque N·m
\(P_d\) Design power W

Method and standards

Gearbox selection.

Where it is used

  • Conveyors, mixers, cranes and agitators.
  • Replacing failed reducers.

Common mistakes

  • Selecting on motor power without the service factor.
  • Ignoring thermal rating.

Assumptions and limits

  • Steady speeds; service factor from the duty.

References

  • Gear reducer selection with service factor

Questions and answers

What gearbox for a 7.5 kW, 1450 rpm motor to 50 rpm?

Ratio 29, output torque about 1,350 N·m; with SF 1.5 select for about 2,000 N·m.

What service factor should I use?

About 1.0 for steady loads 8 h a day, 1.5 for moderate shock or 24 h duty, 2 for heavy shock.

What do the defaults represent?

An illustrative 7.5 kW, 1450 rpm motor driving at 50 rpm through a 94 % efficient reducer with service factor 1.5.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.