Worked example
Example: Illustrative 7.5 kW to 50 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Motor power | 7.5000 kW |
| Input (motor) speed | 1,450.0 rpm |
| Output speed wanted | 50.000 rpm |
| Gearbox efficiency | 94.000 % |
| Service factor for the load and hours | 1.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ratio | 29.000 |
| Output torque | 1,346.5 N·m |
| Design (catalogue) torque | 2,019.7 N·m |
| Design power | 11.250 kW |
Open this example in the calculator and change any input.
Formula
\(i = \frac{n_1}{n_2}, \quad T_2 = \frac{P\eta}{\omega_2}, \quad T_d = SF\cdot T_2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Motor power | W |
| \(n_1\) | Input (motor) speed | rad/s |
| \(n_2\) | Output speed wanted | rad/s |
| \(\eta\) | Gearbox efficiency | - |
| \(SF\) | Service factor for the load and hours | - |
| \(i\) | Ratio | - |
| \(T_2\) | Output torque | N·m |
| \(T_d\) | Design (catalogue) torque | N·m |
| \(P_d\) | Design power | W |
Method and standards
Gearbox selection.
Where it is used
- Conveyors, mixers, cranes and agitators.
- Replacing failed reducers.
Common mistakes
- Selecting on motor power without the service factor.
- Ignoring thermal rating.
Assumptions and limits
- Steady speeds; service factor from the duty.
References
- Gear reducer selection with service factor
Questions and answers
What gearbox for a 7.5 kW, 1450 rpm motor to 50 rpm?
Ratio 29, output torque about 1,350 N·m; with SF 1.5 select for about 2,000 N·m.
What service factor should I use?
About 1.0 for steady loads 8 h a day, 1.5 for moderate shock or 24 h duty, 2 for heavy shock.
What do the defaults represent?
An illustrative 7.5 kW, 1450 rpm motor driving at 50 rpm through a 94 % efficient reducer with service factor 1.5.