Nucleate Boiling: Mostinski, Palen, Cooper and Stephan–Abdelsalam

Nucleate pool boiling coefficient and heat flux from the wall superheat by Mostinski (with Palen's pressure factor), Cooper and Stephan–Abdelsalam correlations.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water at 1 atm, 10 K superheat (contact angle 45 deg)Propane at 10 bar, 8 K superheat

Accepted: 0.1 to 60 K
Accepted: -223.15 to 426.85 °C
Accepted: 1 to 30,000 kPa
Accepted: 100 to 30,000 kPa
Accepted: 2 to 500 kg/kmol
Accepted: 50 to 2,000 kg/m³
Accepted: 0.01 to 500 kg/m³
Accepted: 0.01 to 1 W/(m·K)
Accepted: 0.5 to 10 kJ/(kg·K)
Accepted: 0.1 to 100 mN/m
Accepted: 10 to 3,000 kJ/kg
Accepted: 0.5 to 90 °

Results

Each correlation is written in heat flux and solved for the coefficient with q = h ΔT_e. Predictions for the same case can differ by a factor of ten or more (surface condition dominates); Palen's F_P is the conservative design choice.

Reduced pressure0.004592
Mostinski pressure factor0.72706
Mostinski coefficient8,501.7W/(m²·K)
Mostinski heat flux85.017kW/m²
Palen's pressure factor0.49108
Mostinski coefficient with Palen's F_P2,298.5W/(m²·K)
Heat flux with Palen's F_P22.985kW/m²
Cooper coefficient8,644.7W/(m²·K)
Cooper heat flux86.447kW/m²
Departure bubble diameter2.3267mm
Stephan–Abdelsalam coefficient6,274.9W/(m²·K)
Stephan–Abdelsalam heat flux62.749kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water at 1 atm, 10 K superheat (contact angle 45 deg). The inputs, in the units selected above:

InputValue
Wall superheat T_w − T_sat10.000 K
Saturation temperature99.970 °C
System pressure101.33 kPa
Critical pressure22,064 kPa
Molar mass18.015 kg/kmol
Liquid density958.40 kg/m³
Vapour density0.59800 kg/m³
Liquid thermal conductivity0.67900 W/(m·K)
Liquid specific heat4.2160 kJ/(kg·K)
Surface tension58.900 mN/m
Latent heat2,257.0 kJ/kg
Contact angle (water 45°, organics and refrigerants 35°, cryogens 1°)45.000 °

Applying the formula below gives:

ResultValue
Reduced pressure0.004592
Mostinski pressure factor0.72706
Mostinski coefficient8,501.7 W/(m²·K)
Mostinski heat flux85.017 kW/m²
Palen's pressure factor0.49108
Mostinski coefficient with Palen's F_P2,298.5 W/(m²·K)
Heat flux with Palen's F_P22.985 kW/m²
Cooper coefficient8,644.7 W/(m²·K)
Cooper heat flux86.447 kW/m²
Departure bubble diameter2.3267 mm
Stephan–Abdelsalam coefficient6,274.9 W/(m²·K)
Stephan–Abdelsalam heat flux62.749 kW/m²

Open this example in the calculator and change any input.

Formula

\(h_{nb} = 0.00417P_c^{0.69}\hat q^{0.7}F_P, \quad F_P = 1.8P_r^{0.17} + 4P_r^{1.2} + 10P_r^{10}\)

\(F_P' = 2.1P_r^{0.27} + \left[9 + (1 - P_r^2)^{-1}\right]P_r^2, \quad h_{Cooper} = 55\hat q^{0.67}P_r^{0.12}(-\log_{10}P_r)^{-0.55}M^{-0.5}\)

\(\frac{h d_B}{k_L} = 0.23Z_1^{0.674}Z_2^{0.35}Z_3^{0.371}Z_4^{0.297}Z_5^{-1.73}, \quad d_B = 0.0146\,\theta\left[\frac{2\sigma}{g(\rho_L - \rho_V)}\right]^{1/2}\)

Variables

Symbol Meaning SI unit
\(\Delta T_e\) Wall superheat T_w − T_sat K
\(T_{sat}\) Saturation temperature K
\(P\) System pressure Pa
\(P_c\) Critical pressure Pa
\(M\) Molar mass kg/kmol
\(\rho_L\) Liquid density kg/m³
\(\rho_V\) Vapour density kg/m³
\(k_L\) Liquid thermal conductivity W/(m·K)
\(c_{p,L}\) Liquid specific heat J/(kg·K)
\(\sigma\) Surface tension N/m
\(\lambda\) Latent heat J/kg
\(\theta\) Contact angle (water 45°, organics and refrigerants 35°, cryogens 1°) rad
\(P_r\) Reduced pressure -
\(F_P\) Mostinski pressure factor -
\(h_{nb}\) Mostinski coefficient W/(m²·K)
\(\hat q\) Mostinski heat flux W/m²
\(F_P'\) Palen's pressure factor -
\(h_{nb}'\) Mostinski coefficient with Palen's F_P W/(m²·K)
\(\hat q'\) Heat flux with Palen's F_P W/m²
\(h_{Cooper}\) Cooper coefficient W/(m²·K)
\(\hat q_{Cooper}\) Cooper heat flux W/m²
\(d_B\) Departure bubble diameter m
\(h_{SA}\) Stephan–Abdelsalam coefficient W/(m²·K)
\(\hat q_{SA}\) Stephan–Abdelsalam heat flux W/m²

Method and standards

Corresponding-states and dimensionless nucleate pool boiling correlations (P_c in kPa).

Where it is used

  • Kettle reboiler and vaporiser design.
  • Comparing boiling correlations for an unfamiliar fluid.

Common mistakes

  • Mixing Mostinski's psia form with SI inputs.
  • Forgetting that the contact angle enters in degrees.

Assumptions and limits

  • Pure fluids, nucleate regime below the critical heat flux.

Questions and answers

Which should I design with?

Mostinski with Palen's factor is the conservative choice for reboilers; Cooper is often better for clean surfaces and refrigerants.

What do the defaults represent?

An illustrative case: Water at 1 atm, 10 K superheat (contact angle 45 deg). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.3.1, eqs. 9.2 to 9.13, Table 9.1 and Example 9.1

Related calculators