Worked example
Example: Water at 1 atm on a 10 mm rod at 1000 K (radiation large). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tube outside diameter | 10.000 mm |
| Wall temperature | 726.85 °C |
| Saturation temperature | 100.00 °C |
| Liquid density at T_sat | 958.00 kg/m³ |
| Vapour density (film temperature) | 0.36000 kg/m³ |
| Vapour thermal conductivity | 0.055000 W/(m·K) |
| Vapour viscosity | 0.026000 mPa·s |
| Vapour specific heat | 2.1000 kJ/(kg·K) |
| Latent heat | 2,257.0 kJ/kg |
| Wall emissivity | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wall superheat | 626.85 K |
| Bromley Nusselt number | 36.706 |
| Film boiling coefficient | 201.89 W/(m²·K) |
| Radiative coefficient | 79.834 W/(m²·K) |
| Combined coefficient (exact) | 264.37 W/(m²·K) |
| Combined coefficient, h_fb + 0.75 h_r | 261.76 W/(m²·K) |
| Heat flux | 165.72 kW/m² |
Open this example in the calculator and change any input.
Formula
\(\frac{h_{fb}D_o}{k_V} = 0.62\left[\frac{g\rho_V(\rho_L - \rho_V)D_o^3(\lambda + 0.76c_{p,V}\Delta T_e)}{k_V\mu_V\Delta T_e}\right]^{1/4}\)
\(h_r = \frac{\varepsilon\sigma_{SB}(T_w^4 - T_{sat}^4)}{T_w - T_{sat}}, \quad h_t^{4/3} = h_{fb}^{4/3} + h_rh_t^{1/3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_o\) | Tube outside diameter | m |
| \(T_w\) | Wall temperature | K |
| \(T_{sat}\) | Saturation temperature | K |
| \(\rho_L\) | Liquid density at T_sat | kg/m³ |
| \(\rho_V\) | Vapour density (film temperature) | kg/m³ |
| \(k_V\) | Vapour thermal conductivity | W/(m·K) |
| \(\mu_V\) | Vapour viscosity | Pa·s |
| \(c_{p,V}\) | Vapour specific heat | J/(kg·K) |
| \(\lambda\) | Latent heat | J/kg |
| \(\varepsilon\) | Wall emissivity | - |
| \(\Delta T_e\) | Wall superheat | K |
| \(h_{fb}D_o/k_V\) | Bromley Nusselt number | - |
| \(h_{fb}\) | Film boiling coefficient | W/(m²·K) |
| \(h_r\) | Radiative coefficient | W/(m²·K) |
| \(h_t\) | Combined coefficient (exact) | W/(m²·K) |
| \(h_t'\) | Combined coefficient, h_fb + 0.75 h_r | W/(m²·K) |
| \(\hat q\) | Heat flux | W/m² |
Method and standards
Laminar vapour-film analysis for a horizontal cylinder plus wall radiation.
Where it is used
- Vaporisers with a very hot heating medium.
- Quenching and cryogenic boiling.
Common mistakes
- Using liquid properties for the film.
- Adding radiation linearly when it is large.
Assumptions and limits
- Saturated pool film boiling on a single horizontal tube.
Questions and answers
Why is the coefficient so low?
Heat must cross a vapour film; film boiling coefficients are one to two orders of magnitude below nucleate boiling ones.
Why not add h_r directly?
Radiation thickens the vapour film and lowers the convective part, so Bromley combines them as h_t^(4/3) = h_fb^(4/3) + h_r h_t^(1/3).
What do the defaults represent?
An illustrative case: Water at 1 atm on a 10 mm rod at 1000 K (radiation large). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.6, eqs. 9.101 to 9.104 and Example 9.10 (Bromley 1950; Sadasivan and Lienhard 1987)