FireCADCalc

Critical Heat Flux in Tubes: Palen, Katto–Ohno and Merilo

Critical heat flux for boiling in a uniformly heated tube: Palen's thermosyphon formula, Katto–Ohno for vertical flow and Merilo for horizontal tubes.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water at 70 bar (density ratio above 0.15 branch check) in a 12 mm x 2 m tubeHigh-pressure fluid with density ratio above 0.15, 10 mm x 1.5 m

Accepted: 1 to 10,000 kg/(m²·s)
Accepted: 2 to 100 mm
Accepted: 0.05 to 30 m
Accepted: 0 to 1,000 kJ/kg
Accepted: 1 to 30,000 kPa
Accepted: 100 to 30,000 kPa
Accepted: 50 to 2,000 kg/m³
Accepted: 0.01 to 500 kg/m³
Accepted: 0.001 to 1,000 mPa·s
Accepted: 1E-4 to 1 mPa·s
Accepted: 0.1 to 100 mN/m
Accepted: 10 to 3,000 kJ/kg

Results

Palen ignores flow rate and subcooling. Katto–Ohno is for uniformly heated vertical tubes; Merilo for horizontal tubes (fitted for water and R-12, D 5–19 mm, G 700–8100 kg/(m²·s)). Horizontal tubes dry out at much lower fluxes than vertical ones.

Reduced pressure0.31726
Palen (vertical thermosyphon)192.02kW/m²
Length-to-diameter ratio166.67
Katto–Ohno q_oA2,662.0kW/m²
Katto–Ohno q_oB1,424.1kW/m²
Basic critical heat flux1,424.1kW/m²
Inlet subcooling parameter1.6026
Katto–Ohno (vertical)1,499.9kW/m²
Merilo property group2.1606e+19
Merilo (horizontal)1,145.9kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water at 70 bar (density ratio above 0.15 branch check) in a 12 mm x 2 m tube. The inputs, in the units selected above:

InputValue
Mass flux1,500.0 kg/(m²·s)
Tube inside diameter12.000 mm
Heated length2.0000 m
Inlet subcooling enthalpy50.000 kJ/kg
Pressure7,000.0 kPa
Critical pressure22,064 kPa
Liquid density739.70 kg/m³
Vapour density36.500 kg/m³
Liquid viscosity0.091000 mPa·s
Vapour viscosity0.018900 mPa·s
Surface tension17.700 mN/m
Latent heat1,505.0 kJ/kg

Applying the formula below gives:

ResultValue
Reduced pressure0.31726
Palen (vertical thermosyphon)192.02 kW/m²
Length-to-diameter ratio166.67
Katto–Ohno q_oA2,662.0 kW/m²
Katto–Ohno q_oB1,424.1 kW/m²
Basic critical heat flux1,424.1 kW/m²
Inlet subcooling parameter1.6026
Katto–Ohno (vertical)1,499.9 kW/m²
Merilo property group2.1606e+19
Merilo (horizontal)1,145.9 kW/m²

Open this example in the calculator and change any input.

Formula

\(\hat q_{c,Palen} = 23\,660\left(\frac{D^2}{L}\right)^{0.35}P_c^{0.61}P_r^{0.25}(1 - P_r)\)

\(\hat q_c = \hat q_o\left(1 + \psi\frac{\Delta H_{in}}{\lambda}\right), \quad \frac{\hat q_{oA}}{G\lambda} = \frac{C_2(\sigma\rho_L/G^2L)^{0.043}}{L/D}\)

\(\frac{\hat q_c}{G\lambda} = 575H^{-0.34}\left(\frac{L}{D}\right)^{-0.511}\left(\frac{\rho_L - \rho_V}{\rho_V}\right)^{1.27}\left(1 + \frac{\Delta H_{in}}{\lambda}\right)^{1.64}\)

Variables

Symbol Meaning SI unit
\(G\) Mass flux kg/(m²·s)
\(D\) Tube inside diameter m
\(L\) Heated length m
\(\Delta H_{in}\) Inlet subcooling enthalpy J/kg
\(P\) Pressure Pa
\(P_c\) Critical pressure Pa
\(\rho_L\) Liquid density kg/m³
\(\rho_V\) Vapour density kg/m³
\(\mu_L\) Liquid viscosity Pa·s
\(\mu_V\) Vapour viscosity Pa·s
\(\sigma\) Surface tension N/m
\(\lambda\) Latent heat J/kg
\(P_r\) Reduced pressure -
\(\hat q_{c,Palen}\) Palen (vertical thermosyphon) W/m²
\(L/D\) Length-to-diameter ratio -
\(\hat q_{oA}\) Katto–Ohno q_oA W/m²
\(\hat q_{oB}\) Katto–Ohno q_oB W/m²
\(\hat q_o\) Basic critical heat flux W/m²
\(\psi\) Inlet subcooling parameter -
\(\hat q_{c,KO}\) Katto–Ohno (vertical) W/m²
\(H\) Merilo property group -
\(\hat q_{c,Merilo}\) Merilo (horizontal) W/m²

Method and standards

Empirical critical heat flux correlations for flow boiling in tubes (P_c in kPa).

Where it is used

  • Checking reboiler and vaporiser tubes against dryout.
  • Comparing vertical and horizontal tube boiling.

Common mistakes

  • Using a pool-boiling CHF for tube-side boiling.
  • Forgetting the inlet subcooling term.

Assumptions and limits

  • Uniformly heated round tubes; pure fluids.

Questions and answers

Which Katto–Ohno branch applies?

The density ratio ρ_V/ρ_L decides: up to 0.15 the A, B, C branches; above 0.15 the A, D, E branches. The calculator picks the branch automatically.

What do the defaults represent?

An illustrative case: Water at 70 bar (density ratio above 0.15 branch check) in a 12 mm x 2 m tube. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.5.6, eqs. 9.84 to 9.100 and Examples 9.8 and 9.9 (Palen 1988; Katto and Ohno 1984; Merilo 1979)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.