FireCADCalc

Heat Loss from a Buried Pipe (Conduction Shape Factor)

Heat loss per metre from a buried horizontal pipe to the ground surface by the conduction shape factor, with an optional insulation layer in series.

Process steam and utilitiesRefinery and petrochemical

Inputs

Examples: District heating 200 mm pipe, 1.2 m deep, 80 C, 5 C surface, 60 mm PUR (0.027), soil 1.5

Accepted: 10 to 5,000 mm
Accepted: 0.05 to 50 m
Accepted: 0.1 to 5 W/(m·K)
Accepted: -43.15 to 426.85 °C
Accepted: -53.15 to 56.85 °C
Accepted: 0 to 500 mm
Accepted: 0.01 to 1 W/(m·K)

Results

Shape factor S = 2πL/cosh⁻¹(2z/D) for a long isothermal cylinder in a semi-infinite medium with an isothermal surface. Resistances are in K·m/W. Moist soil conducts 1–2.5 W/(m·K), dry sand 0.3.

Shape factor per metre2.3752
Soil resistance per metre0.28068
Insulation resistance per metre2.5755
Heat loss per metre of pipe26.259W/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: District heating 200 mm pipe, 1.2 m deep, 80 C, 5 C surface, 60 mm PUR (0.027), soil 1.5. The inputs, in the units selected above:

InputValue
Pipe outside diameter (bare)219.00 mm
Depth of the pipe centre below the surface1.2000 m
Soil thermal conductivity1.5000 W/(m·K)
Pipe outer wall temperature80.000 °C
Ground surface temperature5.0000 °C
Insulation thickness (0 = bare)60.000 mm
Insulation conductivity0.027000 W/(m·K)

Applying the formula below gives:

ResultValue
Shape factor per metre2.3752
Soil resistance per metre0.28068
Insulation resistance per metre2.5755
Heat loss per metre of pipe26.259 W/m

Open this example in the calculator and change any input.

Formula

\(S = \frac{2\pi L}{\cosh^{-1}(2z/D)}, \quad q' = \frac{T_p - T_s}{\frac{1}{k_eS/L} + \frac{\ln(D_{ins}/D)}{2\pi k_{ins}}}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe outside diameter (bare) m
\(z\) Depth of the pipe centre below the surface m
\(k_e\) Soil thermal conductivity W/(m·K)
\(T_p\) Pipe outer wall temperature K
\(T_s\) Ground surface temperature K
\(t_{ins}\) Insulation thickness (0 = bare) m
\(k_{ins}\) Insulation conductivity W/(m·K)
\(S/L\) Shape factor per metre -
\(R_e\) Soil resistance per metre -
\(R_{ins}\) Insulation resistance per metre -
\(q'\) Heat loss per metre of pipe W/m

Method and standards

Conduction shape factor for a buried cylinder in series with insulation.

Where it is used

  • District heating and oil pipeline losses.
  • Freeze protection of buried water lines.

Common mistakes

  • Measuring depth to the top of the pipe instead of its centre.
  • Using the soil temperature at depth as the surface temperature.

Assumptions and limits

  • Steady state, uniform soil, long pipe.

Questions and answers

What surface temperature should I use?

The ground surface temperature, close to the air temperature averaged over days; in winter it can be well below the soil temperature at pipe depth.

Does depth matter much?

Only logarithmically: doubling the depth cuts the loss by perhaps 20–30 %.

What do the defaults represent?

An illustrative case: District heating 200 mm pipe, 1.2 m deep, 80 C, 5 C surface, 60 mm PUR (0.027), soil 1.5. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 1.7, Table 1.3, Examples 1.8 and 1.9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.