View Factor between Rectangles: Parallel or Perpendicular

Radiation view factor between two aligned parallel rectangles or two perpendicular rectangles sharing an edge, with the reverse factor by reciprocity.

Inputs

Examples: Illustrative: 2 x 1 m panels facing each other 1 m apartFurnace floor 4 x 3 m to a wall 4 m long and 2.5 m high (common edge)Close parallel plates 1 x 1 m, 0.1 m apart

Accepted: 0.0001 to 1,000 m
Accepted: 0.0001 to 1,000 m
Accepted: 0.0001 to 1,000 m

Results

Analytical view factors for diffuse surfaces; reciprocity A_i F_ij = A_j F_ji gives the reverse factor. Other shapes follow by view factor algebra (sums and differences of rectangles).

View factor from surface i to j0.28588
View factor from j to i0.28588
Area of surface i2.0000m²
Area of surface j2.0000m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 2 x 1 m panels facing each other 1 m apart. The inputs, in the units selected above:

InputValue
GeometryAligned parallel rectangles X × Y, spaced Z apart
Side X (common edge for perpendicular)2.0000 m
Side Y (width of surface i)1.0000 m
Spacing Z (parallel) or height of surface j (perpendicular)1.0000 m

Applying the formula below gives:

ResultValue
View factor from surface i to j0.28588
View factor from j to i0.28588
Area of surface i2.0000 m²
Area of surface j2.0000 m²

Open this example in the calculator and change any input.

Formula

\(\text{parallel: } F_{ij} = \frac{2}{\pi\bar X\bar Y}\left\{\ln\left[\frac{(1 + \bar X^2)(1 + \bar Y^2)}{1 + \bar X^2 + \bar Y^2}\right]^{1/2} + \bar X\sqrt{1 + \bar Y^2}\tan^{-1}\frac{\bar X}{\sqrt{1 + \bar Y^2}} + \bar Y\sqrt{1 + \bar X^2}\tan^{-1}\frac{\bar Y}{\sqrt{1 + \bar X^2}} - \bar X\tan^{-1}\bar X - \bar Y\tan^{-1}\bar Y\right\}\)

\(A_iF_{ij} = A_jF_{ji}\)

Variables

Symbol Meaning SI unit
\(\text{geometry}\) Geometry -
\(X\) Side X (common edge for perpendicular) m
\(Y\) Side Y (width of surface i) m
\(Z\) Spacing Z (parallel) or height of surface j (perpendicular) m
\(F_{ij}\) View factor from surface i to j -
\(F_{ji}\) View factor from j to i -
\(A_i\) Area of surface i m²
\(A_j\) Area of surface j m²

Method and standards

Diffuse-surface view factors.

Where it is used

  • Furnace and kiln wall exchange, heater design.
  • Radiant panels, solar and building radiation.

Common mistakes

  • Swapping the surfaces in the perpendicular case.
  • Forgetting reciprocity for the reverse factor.

Assumptions and limits

  • Diffuse, flat surfaces; no obstruction between them.

References

  • Analytical view factors for aligned parallel and perpendicular rectangles

Questions and answers

What does a view factor of 0.2 mean?

One fifth of the diffuse radiation leaving surface i strikes surface j directly; the rest goes elsewhere in the enclosure.

How do I handle an offset rectangle?

Use view factor algebra: build the surfaces from rectangles that share the formula's geometry and add or subtract the factors.

What do the defaults represent?

An illustrative pair of 2 × 1 m panels facing each other 1 m apart.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), Table 13.2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.