Worked example
Example: Water at 1 atm, wall 110 C (IAPWS properties). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid conductivity | 0.67900 W/(m·K) |
| Liquid specific heat | 4.2160 kJ/(kg·K) |
| Liquid density | 958.40 kg/m³ |
| Vapour density | 0.59800 kg/m³ |
| Surface tension | 58.900 mN/m |
| Liquid viscosity | 0.28200 mPa·s |
| Latent heat | 2,257.0 kJ/kg |
| Wall temperature | 110.00 °C |
| Saturation temperature | 99.970 °C |
| Saturation pressure at the wall temperature | 1.4327 bar |
| System pressure | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Nucleate boiling coefficient | 8,436.0 W/(m²·K) |
| Heat flux | 84.613 kW/m² |
| Zuber critical heat flux | 1,108.9 kW/m² |
| Share of the critical flux | 7.6306 % |
Open this example in the calculator and change any input.
Formula
\(h_{nb} = 0.00122\left[\frac{k_L^{0.79}c_{pL}^{0.45}\rho_L^{0.49}}{\sigma^{0.5}\mu_L^{0.29}\lambda^{0.24}\rho_v^{0.24}}\right](T_w - T_s)^{0.24}(p_w - p_s)^{0.75}\)
\(q_c = 0.131\lambda[\sigma g(\rho_L - \rho_v)\rho_v^2]^{1/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_L\) | Liquid conductivity | W/(m·K) |
| \(c_{pL}\) | Liquid specific heat | J/(kg·K) |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(\rho_v\) | Vapour density | kg/m³ |
| \(\sigma\) | Surface tension | N/m |
| \(\mu_L\) | Liquid viscosity | Pa·s |
| \(\lambda\) | Latent heat | J/kg |
| \(T_w\) | Wall temperature | K |
| \(T_s\) | Saturation temperature | K |
| \(p_w\) | Saturation pressure at the wall temperature | Pa |
| \(p_s\) | System pressure | Pa |
| \(h_{nb}\) | Nucleate boiling coefficient | W/(m²·K) |
| \(q\) | Heat flux | W/m² |
| \(q_c\) | Zuber critical heat flux | W/m² |
| \(q/q_c\) | Share of the critical flux | - |
Method and standards
Forster–Zuber nucleate boiling and Zuber hydrodynamic CHF.
Where it is used
- Reboiler and vaporiser design for organic fluids.
- Checking boiling duties against CHF.
Common mistakes
- Using the system pressure for p_w.
- Applying pool-boiling values to flow boiling.
Assumptions and limits
- Clean surfaces, pure liquids, nucleate regime.
Questions and answers
Why does it need p_w − p_s?
Forster and Zuber express the superheat partly through the vapour-pressure difference that drives bubble growth, which makes the correlation fit different fluids.
How close to CHF may I operate?
Reboilers are usually designed well below the critical flux, often at half of it or less.
What do the defaults represent?
An illustrative case: Water at 1 atm, wall 110 C (IAPWS properties). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 12.11.2, eqs. 12.62 and 12.65 and Example 12.8 (Forster and Zuber, 1955; Zuber, 1958)