Worked example
Example: Small kettle: 120 tubes 3/4 in on 15/16 in triangular, 0.35 m bundle. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Single-tube nucleate boiling coefficient | 2,500.0 W/(m²·K) |
| Natural convection coefficient (hydrocarbons about 250) | 300.00 W/(m²·K) |
| Bundle diameter | 350.00 mm |
| Tube outside diameter | 19.050 mm |
| Tube pitch | 23.800 mm |
| Layout | Triangular (C₁ = 0.866) |
| Number of tubes | 120.00 - |
| Critical heat flux of a single tube | 450.00 kW/m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bundle boiling factor | 1.5484 |
| Bundle boiling coefficient | 4,170.9 W/(m²·K) |
| Bundle geometry parameter | 0.15311 |
| Bundle CHF factor | 0.47463 |
| Bundle critical heat flux | 213.58 kW/m² |
Open this example in the calculator and change any input.
Formula
\(h_b = h_{nb}F_b + h_{nc}, \quad F_b = 1 + 0.1\left[\frac{0.785D_b}{C_1(P_T/D_o)^2D_o} - 1\right]^{0.75}\)
\(\psi_b = \frac{D_b}{n_tD_o}, \quad \hat q_{c,bundle} = \hat q_{c,tube}\,\phi_b, \ \phi_b = 3.1\psi_b\ (\psi_b < 0.323)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h_{nb}\) | Single-tube nucleate boiling coefficient | W/(m²·K) |
| \(h_{nc}\) | Natural convection coefficient (hydrocarbons about 250) | W/(m²·K) |
| \(D_b\) | Bundle diameter | m |
| \(D_o\) | Tube outside diameter | m |
| \(P_T\) | Tube pitch | m |
| \(\text{layout}\) | Layout | - |
| \(n_t\) | Number of tubes | - |
| \(\hat q_{c,tube}\) | Critical heat flux of a single tube | W/m² |
| \(F_b\) | Bundle boiling factor | - |
| \(h_b\) | Bundle boiling coefficient | W/(m²·K) |
| \(\psi_b\) | Bundle geometry parameter | - |
| \(\phi_b\) | Bundle CHF factor | - |
| \(\hat q_{c,bundle}\) | Bundle critical heat flux | W/m² |
Method and standards
Palen's bundle boiling corrections.
Where it is used
- Kettle reboiler and vaporiser design.
- Checking design heat flux against bundle CHF.
Common mistakes
- Using single-tube CHF for a bundle.
- Ignoring natural convection at low superheat.
Assumptions and limits
- Plain-tube kettle bundles; pure or near-pure fluids.
Questions and answers
Why is the bundle CHF so much lower?
Vapour rising from the lower tubes blankets the upper ones; for large bundles the critical flux can be a fifth of a single tube's.
Where does h_nb come from?
From a single-tube nucleate boiling correlation such as Mostinski or Cooper at the wall superheat.
What do the defaults represent?
An illustrative case: Small kettle: 120 tubes 3/4 in on 15/16 in triangular, 0.35 m bundle. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.2, eqs. 9.19, 9.20 and 9.24 (Palen) and Example 9.4