Worked example
Example: Cooling water shell side, 0.6 m shell, 19.05 mm tubes on 23.81 mm triangular pitch, 25 % cut, larger end spaces. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shell-side mass flow | 144,000 kg/h |
| Shell inside diameter | 600.00 mm |
| Diametral shell-to-bundle clearance | 12.000 mm |
| Tube outside diameter | 19.050 mm |
| Tube pitch | 23.810 mm |
| Tube layout | Triangular 30° |
| Number of tubes | 600.00 - |
| Central baffle spacing | 250.00 mm |
| Inlet baffle spacing | 400.00 mm |
| Outlet baffle spacing | 400.00 mm |
| Baffle cut (fraction of shell diameter) | 25.000 % |
| Number of baffles | 18.000 - |
| Pairs of sealing strips | 2.0000 - |
| Tube-to-baffle clearance (radial) | 0.40000 mm |
| Shell-to-baffle clearance (radial) | 1.6000 mm |
| Shell-side fluid viscosity | 0.80000 mPa·s |
| Viscosity ratio bulk to wall | 1.3000 - |
| Specific heat | 4.1800 kJ/(kg·K) |
| Thermal conductivity | 0.61000 W/(m·K) |
| Density | 996.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cross-flow area at the shell centreline | 0.031436 m² |
| Fraction of tubes in cross flow | 63.881 % |
| Tube-to-baffle leakage area | 0.011769 m² |
| Shell-to-baffle leakage area | 0.002011 m² |
| Window flow area | 0.024392 m² |
| Reynolds number (tube OD, mass flux at S_m) | 30,300 |
| Ideal tube bank j-factor | 0.005875 |
| Ideal tube bank Fanning friction factor | 0.10636 |
| Ideal tube bank coefficient | 10,426 W/(m²·K) |
| Baffle window correction | 1.0099 |
| Leakage correction (heat transfer) | 0.61376 |
| Bypass correction (heat transfer) | 0.95914 |
| Unequal spacing correction | 0.96107 |
| Laminar flow correction | 1.0000 |
| Product of the corrections | 0.57138 |
| Shell-side heat transfer coefficient | 5,957.3 W/(m²·K) |
| Tube rows crossed between baffle tips | 14.549 |
| Effective rows crossed in one window | 5.8196 |
| Leakage correction (pressure drop) | 0.40338 |
| Bypass correction (pressure drop) | 0.88382 |
| Ideal pressure drop, one baffle space | 4.8495 kPa |
| Ideal pressure drop, one window | 5.7527 kPa |
| Shell-side pressure drop, nozzle to nozzle (without nozzles) | 76.311 kPa |
Open this example in the calculator and change any input.
Formula
\(h_o = j\,c_pG\,Pr^{-2/3}\phi\,J_cJ_LJ_BJ_RJ_S, \quad G = \dot m/S_m\)
\(\Delta P_f = \left[(n_b - 1)\Delta P_{ideal}R_B + n_b\Delta P_{w,ideal}\right]R_L + 2\Delta P_{ideal}\left(1 + \frac{N_{cw}}{N_c}\right)R_BR_S\)
\(J_L = 0.44(1 - r_s) + [1 - 0.44(1 - r_s)]e^{-2.2r_l}, \quad R_L = e^{-1.33(1 + r_s)r_l^{p}}, \quad J_B = e^{-C_J(S_b/S_m)(1 - \sqrt[3]{2r_{ss}})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Shell-side mass flow | kg/s |
| \(D_s\) | Shell inside diameter | m |
| \(D_s - D_{otl}\) | Diametral shell-to-bundle clearance | m |
| \(D_o\) | Tube outside diameter | m |
| \(P_T\) | Tube pitch | m |
| \(\theta_{tp}\) | Tube layout | - |
| \(n_t\) | Number of tubes | - |
| \(B\) | Central baffle spacing | m |
| \(B_{in}\) | Inlet baffle spacing | m |
| \(B_{out}\) | Outlet baffle spacing | m |
| \(B_c\) | Baffle cut (fraction of shell diameter) | - |
| \(n_b\) | Number of baffles | - |
| \(N_{ss}\) | Pairs of sealing strips | - |
| \(\delta_{tb}\) | Tube-to-baffle clearance (radial) | m |
| \(\delta_{sb}\) | Shell-to-baffle clearance (radial) | m |
| \(\mu\) | Shell-side fluid viscosity | Pa·s |
| \(\mu/\mu_w\) | Viscosity ratio bulk to wall | - |
| \(c_p\) | Specific heat | J/(kg·K) |
| \(k\) | Thermal conductivity | W/(m·K) |
| \(\rho\) | Density | kg/m³ |
| \(S_m\) | Cross-flow area at the shell centreline | m² |
| \(F_c\) | Fraction of tubes in cross flow | - |
| \(S_{tb}\) | Tube-to-baffle leakage area | m² |
| \(S_{sb}\) | Shell-to-baffle leakage area | m² |
| \(S_w\) | Window flow area | m² |
| \(Re\) | Reynolds number (tube OD, mass flux at S_m) | - |
| \(j\) | Ideal tube bank j-factor | - |
| \(f\) | Ideal tube bank Fanning friction factor | - |
| \(h_{ideal}\) | Ideal tube bank coefficient | W/(m²·K) |
| \(J_c\) | Baffle window correction | - |
| \(J_L\) | Leakage correction (heat transfer) | - |
| \(J_B\) | Bypass correction (heat transfer) | - |
| \(J_S\) | Unequal spacing correction | - |
| \(J_R\) | Laminar flow correction | - |
| \(\Pi J\) | Product of the corrections | - |
| \(h_o\) | Shell-side heat transfer coefficient | W/(m²·K) |
| \(N_c\) | Tube rows crossed between baffle tips | - |
| \(N_{cw}\) | Effective rows crossed in one window | - |
| \(R_L\) | Leakage correction (pressure drop) | - |
| \(R_B\) | Bypass correction (pressure drop) | - |
| \(\Delta P_{ideal}\) | Ideal pressure drop, one baffle space | Pa |
| \(\Delta P_{w,ideal}\) | Ideal pressure drop, one window | Pa |
| \(\Delta P_f\) | Shell-side pressure drop, nozzle to nozzle (without nozzles) | Pa |
Method and standards
Ideal tube bank correlations corrected for window flow, leakage, bypass, laminar flow and unequal end spacing.
Where it is used
- Rating shell-and-tube exchangers more accurately than Kern's method.
- Checking a vendor's shell-side film coefficient and pressure drop.
- Judging the effect of sealing strips, clearances and baffle spacing.
Common mistakes
- Entering diametral clearances where radial ones are asked for.
- Using the equivalent diameter in Re instead of the tube OD.
- Forgetting the end spaces, which have no leakage correction.
Assumptions and limits
- E shells with single-segmental baffles and plain tubes; baffle cuts 15–45 %.
- Accuracy about ±25 % for h_o and ±40 % for ΔP (Taborek).
Questions and answers
Which correction matters most?
Usually leakage (J_L, R_L), then bypass (J_B, R_B). Sealing strips cut the bypass; a larger baffle spacing reduces the leakage share.
How do I estimate the clearances?
(after Taborek): tube-to-baffle 0.4 mm, or 0.2 mm for tubes up to 1.25 in with an unsupported length over 0.9 m; shell-to-baffle 0.8 + 0.002 D_s mm; shell-to-bundle from the head type (about 10–20 mm for fixed tubesheets and U-tubes, 30–100 mm for floating heads).
What do the defaults represent?
An illustrative case: Cooling water shell side, 0.6 m shell, 19.05 mm tubes on 23.81 mm triangular pitch, 25 % cut, larger end spaces. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), ch. 6, eqs. 6.1 to 6.57, Table 6.1 and Example 6.1 (Taborek's version of the Delaware method, Heat Exchanger Design Handbook)