FireCADCalc

Agitated Vessel Inside Film and Overall Coefficient

Vessel-side film coefficient of a jacketed or coiled agitated vessel from agitator Reynolds and Prandtl numbers, and the overall coefficient with wall and jacket.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water-like batch, 0.7 m turbine at 90 rpm, coil side, steam 6,000Viscous cooling with a paddle, wall correction 0.5

Accepted: 0.05 to 10 m
Accepted: 0.095493 to 1,909.9 rpm
Accepted: 300 to 2,500 kg/m³
Accepted: 0.1 to 100,000 mPa·s
Accepted: 0.05 to 1 W/(m·K)
Accepted: 0.5 to 6 kJ/(kg·K)
Accepted: 0.01 to 100
Accepted: 10 to 100,000 W/(m²·K)
Accepted: 0 to 100 mm
Accepted: 1 to 400 W/(m·K)
Accepted: 0 to 0.01 m²·K/W

Results

Designers write Nu = h_v d/k_f = C Re^a Pr^0.33 (μ/μ_w)^0.14 with the agitator diameter d in both Nu and Re = ρNd²/μ (eq. 12.85); other texts use the vessel diameter with different constants, so keep each set with its own definition. The wall is treated as flat.

Impeller Reynolds number735,000
Prandtl number6.9667
Nusselt number on agitator diameter9,050.8
Vessel-side coefficient7,757.9W/(m²·K)
Overall coefficient802.85W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water-like batch, 0.7 m turbine at 90 rpm, coil side, steam 6,000. The inputs, in the units selected above:

InputValue
Agitator and surfaceFlat-blade turbine, coil, baffled, Re 2,000 to 700,000 (C 1.10)
Agitator diameter0.70000 m
Impeller speed90.000 rpm
Liquid density1,000.0 kg/m³
Liquid viscosity1.0000 mPa·s
Liquid thermal conductivity0.60000 W/(m·K)
Liquid specific heat4.1800 kJ/(kg·K)
Viscosity ratio bulk to wall (1 to neglect)1.0000 -
Jacket-side coefficient6,000.0 W/(m²·K)
Wall thickness12.000 mm
Wall conductivity (stainless 16)16.000 W/(m·K)
Total fouling resistance2.0000e-04 m²·K/W

Applying the formula below gives:

ResultValue
Impeller Reynolds number735,000
Prandtl number6.9667
Nusselt number on agitator diameter9,050.8
Vessel-side coefficient7,757.9 W/(m²·K)
Overall coefficient802.85 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(\frac{h_vd}{k_f} = C\left(\frac{\rho Nd^2}{\mu}\right)^a\left(\frac{c_p\mu}{k_f}\right)^{0.33}\left(\frac{\mu}{\mu_w}\right)^{0.14}\)

\(\frac{1}{U} = \frac{1}{h_v} + \frac{x_w}{k_w} + \frac{1}{h_j} + R_f\)

Variables

Symbol Meaning SI unit
\(\text{case}\) Agitator and surface -
\(d\) Agitator diameter m
\(N\) Impeller speed rad/s
\(\rho\) Liquid density kg/m³
\(\mu\) Liquid viscosity Pa·s
\(k_f\) Liquid thermal conductivity W/(m·K)
\(c_p\) Liquid specific heat J/(kg·K)
\(\mu/\mu_w\) Viscosity ratio bulk to wall (1 to neglect) -
\(h_j\) Jacket-side coefficient W/(m²·K)
\(x_w\) Wall thickness m
\(k_w\) Wall conductivity (stainless 16) W/(m·K)
\(R_f\) Total fouling resistance m²·K/W
\(Re\) Impeller Reynolds number -
\(Pr\) Prandtl number -
\(Nu\) Nusselt number on agitator diameter -
\(h_v\) Vessel-side coefficient W/(m²·K)
\(U\) Overall coefficient W/(m²·K)

Method and standards

Dimensionless correlation for agitated-vessel wall heat transfer.

Where it is used

  • Batch reactor heating and cooling time estimates.
  • Choosing agitator speed for heat removal.

Common mistakes

  • Using rpm instead of revolutions per second in Re.
  • Mixing constants from a vessel-diameter correlation with this agitator-diameter form.

Assumptions and limits

  • Baffled vessel, turbulent agitation; constants depend on agitator and surface.

Questions and answers

Why does viscosity dominate?

The film coefficient varies roughly as μ^-0.34 through Re and Pr together, so viscous batches heat slowly; a wall-viscosity correction matters when cooling viscous liquids.

How do I get the jacket coefficient?

From the jacket type: steam condensing 5,000–10,000 W/(m²·K), water in a spiral-baffled jacket from a duct correlation, a half-pipe coil from a tube correlation.

What do the defaults represent?

An illustrative case: Water-like batch, 0.7 m turbine at 90 rpm, coil side, steam 6,000. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 12.18, eq. 12.86 and Example 12.15

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.