Worked example
Example: 200→90 against 30→130 (cross). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hot fluid in | 200.00 °C |
| Hot fluid out | 90.000 °C |
| Cold fluid in | 30.000 °C |
| Cold fluid out | 130.00 °C |
| Minimum acceptable F | 0.80000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Overall thermal effectiveness (cold side) | 0.58824 |
| Capacity ratio | 1.1000 |
| Shells in series needed | 2.0000 |
| F with N shells | 0.87948 |
| Corrected mean temperature difference | 57.053 K |
Open this example in the calculator and change any input.
Formula
\(P = \frac{t_{c,o} - t_{c,i}}{T_{h,i} - t_{c,i}}, \ R = \frac{T_{h,i} - T_{h,o}}{t_{c,o} - t_{c,i}}, \quad P_1 = \frac{1 - X}{R - X}, \ X = \left(\frac{1 - PR}{1 - P}\right)^{1/N}\)
\(F = \frac{\sqrt{R^2 + 1}}{R - 1}\frac{\ln\frac{1 - P_1}{1 - P_1R}}{\ln\frac{2 - P_1(R + 1 - \sqrt{R^2 + 1})}{2 - P_1(R + 1 + \sqrt{R^2 + 1})}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{h,in}\) | Hot fluid in | K |
| \(T_{h,out}\) | Hot fluid out | K |
| \(T_{c,in}\) | Cold fluid in | K |
| \(T_{c,out}\) | Cold fluid out | K |
| \(F_{min}\) | Minimum acceptable F | - |
| \(P\) | Overall thermal effectiveness (cold side) | - |
| \(R\) | Capacity ratio | - |
| \(F_1\) | F with one shell | - |
| \(N\) | Shells in series needed | - |
| \(F_N\) | F with N shells | - |
| \(F_N\Delta T_{lm}\) | Corrected mean temperature difference | K |
Method and standards
Bowman's F for 1-2 shells, applied per shell for N shells in series.
Where it is used
- Shell-and-tube exchanger layout.
- Feed–effluent exchangers with close approaches.
Common mistakes
- Accepting F below 0.75.
- Ignoring the cross when only checking LMTD.
Assumptions and limits
- Each shell one shell pass and an even number of tube passes.
- When one shell cannot reach the temperatures at all, F₁ is not shown and a note says so.
References
- Bowman
- Mueller and Nagle
- Trans. ASME 62: 283 (1940): F for 1-2 shells and N shells in series (Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 11, Fig. 11-4)
Questions and answers
What is a temperature cross?
The cold outlet is hotter than the hot outlet; a single 1-2 shell cannot achieve it efficiently because part of its surface works in parallel flow.
Why add shells in series?
Each shell does part of the duty with less crossing, so the overall arrangement approaches true counterflow.
What do the defaults give?
200 → 90 °C against 30 → 130 °C: F is far too low in one shell; two shells in series give F about 0.88.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.