Worked example
Example: Water, 292 tubes, 2 passes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tube-side mass flow | 108,000 kg/h |
| Fluid density | 995.00 kg/m³ |
| Fluid viscosity | 8.0000e-04 Pa·s |
| Tube inside diameter | 15.750 mm |
| Number of tubes | 292.00 - |
| Tube passes | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tube-side velocity | 1.0600 m/s |
| Reynolds number | 20,764 |
Open this example in the calculator and change any input.
Formula
\(v = \frac{\dot m}{\rho\frac{N}{n_p}\frac{\pi d_i^2}{4}}, \quad Re = \frac{\rho v d_i}{\mu}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Tube-side mass flow | kg/s |
| \(\rho\) | Fluid density | kg/m³ |
| \(\mu\) | Fluid viscosity | Pa·s |
| \(d_i\) | Tube inside diameter | m |
| \(N\) | Number of tubes | - |
| \(n_p\) | Tube passes | - |
| \(v\) | Tube-side velocity | m/s |
| \(Re\) | Reynolds number | - |
Method and standards
Continuity.
Where it is used
- Exchanger rating.
- Cooling water exchangers.
Common mistakes
- All tubes instead of tubes per pass.
- Outside diameter.
Assumptions and limits
- Equal flow in every tube.
References
- Continuity per pass v = ṁ/(ρ (N/n_p) π d_i²/4)
Questions and answers
30 kg/s of water in 292 tubes, two passes, 15.75 mm bore?
About 1.06 m/s, Re about 20,764.
Too low?
Add passes to raise velocity and heat transfer, at more pressure drop.
Too high?
Erosion and vibration; reduce passes.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.