Jacketed Reactor: Duty and Jacket Fluid Flow (Isothermal Batch)

Heat transfer through a reactor jacket or coil to an isothermal batch from U, area and jacket fluid inlet and outlet temperatures, and the jacket fluid flow.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Cooling a batch at 80 °CHeating with hot oil

Results

Log mean temperature difference44.814K
Heat transfer (positive: batch cooled)188.22kW
Jacket fluid flow16.210t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cooling a batch at 80 °C. The inputs, in the units selected above:

InputValue
Overall coefficient350.00 W/(m²·K)
Jacket or coil area12.000 m²
Batch temperature80.000 °C
Jacket fluid in30.000 °C
Jacket fluid out40.000 °C
Jacket fluid specific heat4.1800 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Log mean temperature difference44.814 K
Heat transfer (positive: batch cooled)188.22 kW
Jacket fluid flow16.210 t/h

Open this example in the calculator and change any input.

Formula

\(\Delta T_{lm} = \frac{(T_r - t_1) - (T_r - t_2)}{\ln\frac{T_r - t_1}{T_r - t_2}}, \quad \dot Q = U A \Delta T_{lm}, \quad \dot m = \frac{\dot Q}{c(t_2 - t_1)}\)

Variables

Symbol Meaning SI unit
\(U\) Overall coefficient W/(m²·K)
\(A\) Jacket or coil area m²
\(T_r\) Batch temperature K
\(t_1\) Jacket fluid in K
\(t_2\) Jacket fluid out K
\(c\) Jacket fluid specific heat J/(kg·K)
\(\Delta T_{lm}\) Log mean temperature difference K
\(\dot Q\) Heat transfer (positive: batch cooled) W
\(\dot m\) Jacket fluid flow kg/s

Method and standards

LMTD.

Where it is used

  • Reactor and crystalliser jackets.
  • Cooling water planning.

Common mistakes

  • Arithmetic mean ΔT.
  • Ignoring fouling in U.

Assumptions and limits

  • Well-mixed batch at constant temperature.
  • The jacket fluid must warm when it cools the batch and cool when it heats it; other combinations are rejected.

References

  • Q = U A ΔT_lm with the batch at uniform temperature; jacket flow from its temperature change

Questions and answers

U 350, 12 m², batch 80 °C, water 30 → 40 °C?

ΔT_lm 44.8 K: 188 kW and 16.2 t/h of water.

Heating?

Enter jacket temperatures above the batch: the duty shows negative (heat into the batch).

Where does U come from?

Film coefficients, wall and fouling, or a plant test.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.