FireCADCalc

Reactor Heat Removal and Cooling Water Flow

Heat to remove from an exothermic reactor from the reaction rate, volume, heat of reaction and agitator power, and the cooling water flow (IF97).

Refinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: 10 m3 exothermicFermenter

Results

Water enthalpies at 3 bar(a) (IAPWS-IF97). Size for the peak rate, not the average.

Heat to remove67.500kW
Cooling water flow7.2696t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m3 exothermic. The inputs, in the units selected above:

InputValue
Reaction rate, mol of key reactant per m³ per second0.050000 -
Reacting volume10.000 m³
Heat of reaction (negative: exothermic)-120.00 kJ/mol
Agitator power to the liquid7.5000 kW
Cooling water in32.000 °C
Cooling water out40.000 °C

Applying the formula below gives:

ResultValue
Heat to remove67.500 kW
Cooling water flow7.2696 t/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = r V(-\Delta H_r) + P_a, \quad \dot m = \frac{\dot Q}{h(t_2) - h(t_1)}\)

Variables

Symbol Meaning SI unit
\(r\) Reaction rate, mol of key reactant per m³ per second -
\(V\) Reacting volume m³
\(\Delta H_r\) Heat of reaction (negative: exothermic) J/mol
\(P_a\) Agitator power to the liquid W
\(t_1\) Cooling water in K
\(t_2\) Cooling water out K
\(\dot Q\) Heat to remove W
\(\dot m\) Cooling water flow kg/s

Method and standards

Energy balance.

Where it is used

  • Reactor and fermenter cooling.
  • Cooling tower and pump sizing.

Common mistakes

  • Average instead of peak rate.
  • Forgetting agitator heat.

Assumptions and limits

  • Steady state.
  • The rate r is a plain number in mol of key reactant per m³ per second, and ΔH_r must be per mol of the same key reactant.

References

  • Heat generation r V (−ΔH_r) plus agitator power; water enthalpies from IAPWS-IF97

Questions and answers

0.05 mol/(m³·s) in 10 m³ at −120 kJ/mol plus 7.5 kW of agitation?

67.5 kW: about 7.3 t/h of water for an 8 K rise.

Why add agitator power?

It all ends up as heat in the liquid.

Batch reactors?

The rate peaks early; size for the peak.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.