Worked example
Example: Water, 0.5 m shell, 19.05 mm tubes on 23.81 mm triangular, B = 0.2 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shell-side mass flow | 90,000 kg/h |
| Shell inside diameter | 500.00 mm |
| Tube outside diameter | 19.050 mm |
| Tube pitch | 23.810 mm |
| Tube layout | Triangular |
| Baffle spacing | 200.00 mm |
| Number of baffles | 20.000 - |
| Shell-side fluid viscosity | 0.70000 mPa·s |
| Viscosity ratio bulk to wall | 1.2000 - |
| Specific heat | 4.1800 kJ/(kg·K) |
| Thermal conductivity | 0.62000 W/(m·K) |
| Density | 995.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equivalent diameter | 13.764 mm |
| Flow area across the bundle | 0.019992 m² |
| Mass flux | 1,250.5 kg/(m²·s) |
| Reynolds number (equivalent diameter) | 24,590 |
| Modified Colburn factor | 58.290 |
| Shell-side heat transfer coefficient | 4,517.9 W/(m²·K) |
| Friction factor at B/d_s = 1, ft²/in² | 0.003071 |
| Friction factor at B/d_s = 0.2, ft²/in² | 5.6063e-04 |
| Shell-side friction factor | 0.17111 |
| Shell-side pressure drop (without nozzles) | 99.988 kPa |
Open this example in the calculator and change any input.
Formula
\(j_H = 0.5\left(1 + \frac{B}{d_s}\right)\left(0.08Re^{0.6821} + 0.7Re^{0.1772}\right), \quad h_o = j_H\frac{k}{D_e}Pr^{1/3}\phi\)
\(\Delta P_f = \frac{fG^2d_s(n_b + 1)}{2\rho D_e\phi}, \quad f = 144\left[f_1 - 1.25\left(1 - \frac{B}{d_s}\right)(f_1 - f_2)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Shell-side mass flow | kg/s |
| \(d_s\) | Shell inside diameter | m |
| \(D_o\) | Tube outside diameter | m |
| \(P_T\) | Tube pitch | m |
| \(\text{layout}\) | Tube layout | - |
| \(B\) | Baffle spacing | m |
| \(n_b\) | Number of baffles | - |
| \(\mu\) | Shell-side fluid viscosity | Pa·s |
| \(\mu/\mu_w\) | Viscosity ratio bulk to wall | - |
| \(c_p\) | Specific heat | J/(kg·K) |
| \(k\) | Thermal conductivity | W/(m·K) |
| \(\rho\) | Density | kg/m³ |
| \(D_e\) | Equivalent diameter | m |
| \(a_s\) | Flow area across the bundle | m² |
| \(G\) | Mass flux | kg/(m²·s) |
| \(Re\) | Reynolds number (equivalent diameter) | - |
| \(j_H\) | Modified Colburn factor | - |
| \(h_o\) | Shell-side heat transfer coefficient | W/(m²·K) |
| \(f_1\) | Friction factor at B/d_s = 1, ft²/in² | - |
| \(f_2\) | Friction factor at B/d_s = 0.2, ft²/in² | - |
| \(f\) | Shell-side friction factor | - |
| \(\Delta P_f\) | Shell-side pressure drop (without nozzles) | Pa |
Method and standards
Simplified Delaware shell-side correlations with Kern's equivalent diameter.
Where it is used
- First-pass rating and design of shell-and-tube exchangers.
- Hand checks of simulator results.
Common mistakes
- Using it for baffle cuts other than 20 %.
- Forgetting that h_o includes a safety factor.
Assumptions and limits
- 20 % cut segmental baffles, plain or low-fin tubes; shells 8–42 in.
Questions and answers
How does it differ from the full Delaware method?
It folds the leakage and bypass effects for standard TEMA clearances into one j_H curve with about 25 % margin.1 shows a 22 % lower h_o than the full method.
Why is the baffle cut fixed at 20 %?
The correlation was fitted to that cut; for other cuts use the Bell–Delaware calculator.
What do the defaults represent?
An illustrative case: Water, 0.5 m shell, 19.05 mm tubes on 23.81 mm triangular, B = 0.2 m. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 3.8 (eqs. 3.20, 3.21, Fig. 3.12), sec. 5.3.2 (eqs. 5.6 to 5.11), Appendix 5.A and Example 5.1