Worked example
Example: High-NTU counterflow, 50:50 split, 1.3 x velocity. The inputs, in the units selected above:
| Input | Value |
|---|---|
| NTU of the maldistributed fluid (UA/C₁) | 8.0000 - |
| Heat capacity rate ratio C₁/C₂ | 1.0000 - |
| Share of free-flow area with the higher velocity | 50.000 % |
| Velocity in that share relative to the mean | 1.3000 - |
| Flow arrangement | Counterflow |
| Pressure drop exponent, Δp ∝ uⁿ (1 laminar, about 1.8 turbulent) | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Velocity in the remaining area relative to the mean | 0.70000 |
| Share of fluid 1 capacity rate in part A | 65.000 % |
| NTU of sub-exchanger A | 6.1538 |
| NTU of sub-exchanger B | 11.429 |
| Capacity ratio of sub-exchanger A | 1.3000 |
| Capacity ratio of sub-exchanger B | 0.70000 |
| Effectiveness of sub-exchanger A | 73.734 % |
| Effectiveness of sub-exchanger B | 99.004 % |
| Effectiveness with maldistribution | 82.579 % |
| Effectiveness with uniform flow | 88.889 % |
| Deterioration factor (P_ideal − P)/P_ideal | 7.0991 % |
| Approximate pressure drop increase factor | 1.3000 |
Open this example in the calculator and change any input.
Formula
\(P_1 = \frac{C_{1,A}}{C_1}P_{1,A} + \frac{C_{1,B}}{C_1}P_{1,B}, \quad \frac{C_{1,A}}{C_1} = \frac{u_A}{u}\frac{A_{o,A}}{A_o}\)
\(NTU_{1,A} = NTU_1\frac{A_{o,A}/A_o}{C_{1,A}/C_1}, \quad R_{1,A} = R_1\frac{C_{1,A}/C_1}{A_{o,A}/A_o}, \quad \Delta P_1^* = \frac{P_{1,ideal} - P_1}{P_{1,ideal}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(NTU_1\) | NTU of the maldistributed fluid (UA/C₁) | - |
| \(R_1\) | Heat capacity rate ratio C₁/C₂ | - |
| \(A_{o,A}/A_o\) | Share of free-flow area with the higher velocity | - |
| \(u_A/u\) | Velocity in that share relative to the mean | - |
| \(\text{flow}\) | Flow arrangement | - |
| \(n\) | Pressure drop exponent, Δp ∝ uⁿ (1 laminar, about 1.8 turbulent) | - |
| \(u_B/u\) | Velocity in the remaining area relative to the mean | - |
| \(C_{1,A}/C_1\) | Share of fluid 1 capacity rate in part A | - |
| \(NTU_{1,A}\) | NTU of sub-exchanger A | - |
| \(NTU_{1,B}\) | NTU of sub-exchanger B | - |
| \(R_{1,A}\) | Capacity ratio of sub-exchanger A | - |
| \(R_{1,B}\) | Capacity ratio of sub-exchanger B | - |
| \(P_{1,A}\) | Effectiveness of sub-exchanger A | - |
| \(P_{1,B}\) | Effectiveness of sub-exchanger B | - |
| \(P_1\) | Effectiveness with maldistribution | - |
| \(P_{1,ideal}\) | Effectiveness with uniform flow | - |
| \(\Delta P_1^*\) | Deterioration factor (P_ideal − P)/P_ideal | - |
| \(\Delta p_{max}/\Delta p_{uniform}\) | Approximate pressure drop increase factor | - |
Method and standards
Parallel sub-exchanger model of gross flow maldistribution on one fluid side.
Where it is used
- Judging the effect of poor header or nozzle design.
- Plate and compact exchangers with uneven port distribution.
Common mistakes
- Assuming maldistribution always costs little: at high NTU and with laminar flow it can be large.
- Forgetting that the fast passages also raise the pressure drop.
Assumptions and limits
- Counterflow or parallelflow, constant U, uniform flow on the other side.
Questions and answers
Why is the loss only a few per cent?
Effectiveness curves flatten at high NTU, so the fast passages lose less than the slow ones gain; the loss grows with NTU for balanced counterflow and is worst for a 50:50 split.
Does it matter which fluid is maldistributed?
No: the analysis holds whether the maldistributed fluid is hot or cold, C_min or C_max.
What do the defaults represent?
An illustrative case: High-NTU counterflow, 50:50 split, 1.3 x velocity. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), sec. 12.1.1, eqs. 12.4 to 12.16 and Example 12.1