Heat Exchangers Coupled in Series: Overall Effectiveness

Overall temperature effectiveness and outlet temperatures of up to four exchangers coupled in overall counterflow or parallelflow, from each unit's effectiveness.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Three 1-2 shells (P 0.45 each) in counterflow, R = 0.6Four units in counterflow, R = 1.5 (fluid 1 the larger-C stream reversed)

Accepted: 0 to 100 %
Accepted: 0 to 100 %
Accepted: 0 to 100 %
Accepted: 0 to 100 %
Accepted: 0 to 20
Accepted: -272.15 to 2,226.8 °C
Accepted: -272.15 to 2,226.8 °C

Results

Fluids are mixed between exchangers; R₁ is the same for every exchanger. Each P is the temperature effectiveness of fluid 1 in that exchanger (from its own NTU, R and flow arrangement). A positive T₁,i − T₂,i means fluid 1 is the hot fluid.

Number of exchangers3.0000
Overall effectiveness (fluid 1)76.988%
Overall effectiveness (fluid 2) = P₁R₁46.193%
Fluid 1 outlet temperature57.615°C
Fluid 2 outlet temperature85.431°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Three 1-2 shells (P 0.45 each) in counterflow, R = 0.6. The inputs, in the units selected above:

InputValue
Effectiveness of exchanger 145.000 %
Effectiveness of exchanger 2 (0 if absent)45.000 %
Effectiveness of exchanger 3 (0 if absent)45.000 %
Effectiveness of exchanger 4 (0 if absent)0 %
Heat capacity rate ratio C₁/C₂0.60000 -
Overall couplingOverall counterflow
Fluid 1 inlet temperature150.00 °C
Fluid 2 inlet temperature30.000 °C

Applying the formula below gives:

ResultValue
Number of exchangers3.0000
Overall effectiveness (fluid 1)76.988 %
Overall effectiveness (fluid 2) = P₁R₁46.193 %
Fluid 1 outlet temperature57.615 °C
Fluid 2 outlet temperature85.431 °C

Open this example in the calculator and change any input.

Formula

\(P_{cf} = \frac{\prod_i\frac{1 - RP_i}{1 - P_i} - 1}{\prod_i\frac{1 - RP_i}{1 - P_i} - R}, \quad P_{cf}(R = 1) = \frac{\sum_iP_i/(1 - P_i)}{1 + \sum_iP_i/(1 - P_i)}\)

\(P_{pf} = \frac{1}{1 + R}\left\{1 - \prod_i\left[1 - (1 + R)P_i\right]\right\}\)

Variables

Symbol Meaning SI unit
\(P_1\) Effectiveness of exchanger 1 -
\(P_2\) Effectiveness of exchanger 2 (0 if absent) -
\(P_3\) Effectiveness of exchanger 3 (0 if absent) -
\(P_4\) Effectiveness of exchanger 4 (0 if absent) -
\(R_1\) Heat capacity rate ratio C₁/C₂ -
\(\text{coupling}\) Overall coupling -
\(T_{1,i}\) Fluid 1 inlet temperature K
\(T_{2,i}\) Fluid 2 inlet temperature K
\(n\) Number of exchangers -
\(T_{1,o}\) Fluid 1 outlet temperature K
\(T_{2,o}\) Fluid 2 outlet temperature K

Method and standards

Effectiveness of exchangers coupled in series in overall counterflow or parallelflow.

Where it is used

  • Trains of shells or exchangers in series.
  • Exchanger networks and heat recovery trains.

Common mistakes

  • Adding effectivenesses directly.
  • Mixing up which fluid R refers to.

Assumptions and limits

  • Same R for every unit; fluids mixed between units.

Questions and answers

When is overall counterflow coupling worth it?

Whenever the units are individually effective: counterflow coupling of two 0.61 and 0.75 units gives 0.82, while parallel coupling can never exceed 1/(1 + R).

How do I combine mixed arrangements?

Combine the counterflow-coupled group first, then treat its result as one exchanger in the next step.

What do the defaults represent?

An illustrative case: Three 1-2 shells (P 0.45 each) in counterflow, R = 0.6. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), sec. 3.6.2, eqs. 3.125 and 3.140 and Example 3.4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.