Worked example
Example: Oil cooler: 1.25 in in 2 in pipe, 6 m legs, oil in annulus, water inside. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat duty | 60.000 kW |
| Mean temperature difference | 40.000 K |
| Inner tube inside diameter | 35.100 mm |
| Inner tube outside diameter | 42.200 mm |
| Outer pipe inside diameter | 52.500 mm |
| Hairpin leg length | 6.0000 m |
| Inner tube wall conductivity | 45.000 W/(m·K) |
| Fouling resistance, inside | 1.7600e-04 m²·K/W |
| Fouling resistance, annulus side | 3.5200e-04 m²·K/W |
| Inner tube flow | 5,400.0 kg/h |
| Inner fluid density | 995.00 kg/m³ |
| Inner fluid viscosity | 0.80000 mPa·s |
| Inner fluid conductivity | 0.62000 W/(m·K) |
| Inner fluid Prandtl number | 5.4000 - |
| Annulus flow | 7,200.0 kg/h |
| Annulus fluid density | 860.00 kg/m³ |
| Annulus fluid viscosity | 3.0000 mPa·s |
| Annulus fluid conductivity | 0.13000 W/(m·K) |
| Annulus fluid Prandtl number | 45.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inner tube velocity | 1.5580 m/s |
| Inner Reynolds number | 68,015 |
| Inner film coefficient | 5,482.7 W/(m²·K) |
| Annulus velocity | 3.0357 m/s |
| Annulus Reynolds number (on D_h) | 8,963.3 |
| Annulus film coefficient (on D_e) | 362.67 W/(m²·K) |
| Fouled overall coefficient (outside area) | 275.74 W/(m²·K) |
| Clean overall coefficient | 326.48 W/(m²·K) |
| Required outside area | 5.4399 m² |
| Hairpins required (exact) | 3.4194 |
| Hairpins installed (rounded up) | 4.0000 |
| Inner tube pressure drop (straight lengths) | 32.297 kPa |
| Annulus pressure drop (straight lengths) | 599.57 kPa |
Open this example in the calculator and change any input.
Formula
\(Nu = \frac{(f/2)RePr}{1 + 8.7(f/2)^{1/2}(Pr - 1)}, \quad f = (1.58\ln Re - 3.28)^{-2}\)
\(\frac{1}{U_f} = \frac{d_o}{d_ih_i} + \frac{d_oR_{fi}}{d_i} + \frac{d_o\ln(d_o/d_i)}{2k_w} + R_{fo} + \frac{1}{h_o}, \quad \Delta p = 4f\frac{2LN_{hp}}{D}\frac{\rho u^2}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Heat duty | W |
| \(\Delta T_m\) | Mean temperature difference | K |
| \(d_i\) | Inner tube inside diameter | m |
| \(d_o\) | Inner tube outside diameter | m |
| \(D_i\) | Outer pipe inside diameter | m |
| \(L\) | Hairpin leg length | m |
| \(k_w\) | Inner tube wall conductivity | W/(m·K) |
| \(R_{fi}\) | Fouling resistance, inside | m²·K/W |
| \(R_{fo}\) | Fouling resistance, annulus side | m²·K/W |
| \(\dot m_i\) | Inner tube flow | kg/s |
| \(\rho_i\) | Inner fluid density | kg/m³ |
| \(\mu_i\) | Inner fluid viscosity | Pa·s |
| \(k_i\) | Inner fluid conductivity | W/(m·K) |
| \(Pr_i\) | Inner fluid Prandtl number | - |
| \(\dot m_a\) | Annulus flow | kg/s |
| \(\rho_a\) | Annulus fluid density | kg/m³ |
| \(\mu_a\) | Annulus fluid viscosity | Pa·s |
| \(k_a\) | Annulus fluid conductivity | W/(m·K) |
| \(Pr_a\) | Annulus fluid Prandtl number | - |
| \(u_i\) | Inner tube velocity | m/s |
| \(Re_i\) | Inner Reynolds number | - |
| \(h_i\) | Inner film coefficient | W/(m²·K) |
| \(u_a\) | Annulus velocity | m/s |
| \(Re_a\) | Annulus Reynolds number (on D_h) | - |
| \(h_o\) | Annulus film coefficient (on D_e) | W/(m²·K) |
| \(U_f\) | Fouled overall coefficient (outside area) | W/(m²·K) |
| \(U_c\) | Clean overall coefficient | W/(m²·K) |
| \(A_o\) | Required outside area | m² |
| \(A_o/A_{hp}\) | Hairpins required (exact) | - |
| \(N_{hp}\) | Hairpins installed (rounded up) | - |
| \(\Delta p_i\) | Inner tube pressure drop (straight lengths) | Pa |
| \(\Delta p_a\) | Annulus pressure drop (straight lengths) | Pa |
Method and standards
Double-pipe exchanger thermal design.
Where it is used
- Small process heaters and coolers.
- Sizing hairpins for high-pressure duties.
Common mistakes
- Using D_h for the annulus heat-transfer coefficient.
- Forgetting the return-bend losses.
Assumptions and limits
- Turbulent flow, counterflow, constant properties.
Questions and answers
Why two different diameters for the annulus?
Friction acts on both walls, so the hydraulic diameter D_i − d_o sets Re and Δp; heat passes only through the inner tube, so the heat-transfer diameter is (D_i² − d_o²)/d_o.
When are hairpins chosen?
For small duties (below about 50 m²), high pressures or temperature crosses, since true counterflow is possible.
What do the defaults represent?
An illustrative case: Oil cooler: 1.25 in in 2 in pipe, 6 m legs, oil in annulus, water inside. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Kakaç, Liu and Pramuanjaroenkij, Heat Exchangers: Selection, Rating and Thermal Design, 3rd ed. (CRC Press, 2012), sec. 7.3, eqs. 7.1 to 7.7 and Example 7.1