Worked example
Example: Steam at 0.5 bar condensing in 40 vertical tubes (turbulent film). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condensate flow | 10,800 kg/h |
| Condenser type | Vertical, condensing inside the tubes |
| Number of tubes | 40.000 - |
| Tube length | 6.0000 m |
| Tube inside diameter | 22.000 mm |
| Tube outside diameter | 25.000 mm |
| Condensate density | 965.00 kg/m³ |
| Vapour density | 0.31000 kg/m³ |
| Condensate viscosity | 0.32000 mPa·s |
| Condensate thermal conductivity | 0.67000 W/(m·K) |
| Condensate specific heat | 4.2000 kJ/(kg·K) |
| Latent heat | 2,305.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Condensate loading | 1.0851 kg/m |
| Film Reynolds number 4Γ/μ_L | 13,564 |
| Film regime (1 laminar, 2 wavy, 3 turbulent; 0 horizontal bundle) | 3.0000 |
| Condensing coefficient | 8,142.6 W/(m²·K) |
| Condensing surface | 16.588 m² |
| Film temperature drop | 51.197 K |
| Condensate Prandtl number | 2.0060 |
| Jakob number c_pΔT/λ | 0.093288 |
| Subcooling correction (Sadasivan–Lienhard) | 1.0130 |
| Coefficient with subcooling correction | 8,248.6 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(\text{vertical: } \Gamma = \frac{W}{n_t\pi D_i}, \; Re = \frac{4\Gamma}{\mu_L}, \; h = \frac{Re\,K}{1.08Re^{1.22} - 5.2}\;(30 < Re \le 1600), \quad K = \left[\frac{k_L^3\rho_L(\rho_L - \rho_V)g}{\mu_L^2}\right]^{1/3}\)
\(\text{horizontal: } h = 1.52\left[\frac{k_L^3\rho_L(\rho_L - \rho_V)g}{4\mu_L\Gamma^*}\right]^{1/3}, \quad \Gamma^* = \frac{W}{Ln_t^{2/3}}, \quad \frac{h}{h_{Nu}} = \left[1 + \left(0.683 - \frac{0.228}{Pr_L}\right)\zeta\right]^{1/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Condensate flow | kg/s |
| \(\text{bundle}\) | Condenser type | - |
| \(n_t\) | Number of tubes | - |
| \(L\) | Tube length | m |
| \(D_i\) | Tube inside diameter | m |
| \(D_o\) | Tube outside diameter | m |
| \(\rho_L\) | Condensate density | kg/m³ |
| \(\rho_V\) | Vapour density | kg/m³ |
| \(\mu_L\) | Condensate viscosity | Pa·s |
| \(k_L\) | Condensate thermal conductivity | W/(m·K) |
| \(c_{p,L}\) | Condensate specific heat | J/(kg·K) |
| \(\lambda\) | Latent heat | J/kg |
| \(\Gamma\) | Condensate loading | kg/m |
| \(Re_f\) | Film Reynolds number 4Γ/μ_L | - |
| \(\text{regime}\) | Film regime (1 laminar, 2 wavy, 3 turbulent; 0 horizontal bundle) | - |
| \(h\) | Condensing coefficient | W/(m²·K) |
| \(A\) | Condensing surface | m² |
| \(T_{sat} - T_w\) | Film temperature drop | K |
| \(Pr_L\) | Condensate Prandtl number | - |
| \(\zeta\) | Jakob number c_pΔT/λ | - |
| \(h/h_{Nu}\) | Subcooling correction (Sadasivan–Lienhard) | - |
| \(h_c\) | Coefficient with subcooling correction | W/(m²·K) |
Method and standards
Nusselt film condensation with wavy and turbulent film corrections and Kern's bundle drainage allowance.
Where it is used
- Sizing overhead condensers and vapour condensers.
- Choosing between vertical and horizontal condenser layouts.
Common mistakes
- Using the vapour flow per tube for a horizontal bundle without Kern's n_t^(2/3).
- Ignoring the change of viscosity with the wall temperature.
Assumptions and limits
- Pure saturated vapours, gravity-controlled films.
Questions and answers
Why does the horizontal bundle give a higher coefficient?
Each tube carries a short film; even with Kern's n_t^(2/3) drainage allowance the film stays thinner than on a long vertical tube.
Is the vapour density needed?
Only at higher pressures; at about 1 atm it is negligible next to the liquid density, as Designers assume.
What do the defaults represent?
An illustrative case: Steam at 0.5 bar condensing in 40 vertical tubes (turbulent film). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), secs. 11.3 to 11.5, eqs. 11.26, 11.35, 11.36, 11.39, 11.40, 11.47 and Examples 11.1 and 11.2